Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/10/2017

Applicant:

CATALINA INVESTMENTS LLC ATTN: MOISE HENDELES

Description:

WATER LEAK IN THE APARTMENT CAUSING SOME ROOMS TO BE UNUSEABLE

Case Violations

Case Number: T17DV03593
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
Violation Date Code Statue
08/16/2017 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
08/16/2017 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
08/16/2017 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
08/16/2017 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
08/16/2017 T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.
08/16/2017 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
08/16/2017 T.C. Ch. 16, Sec. 16-11(f)(6) All repair work shall be done in a workman like manner.

Outstanding Inspections

Case Number: T17DV03593
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
10/05/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX MENDOZA Item closed
10/05/2017 NPO(PL)-PLUMBING SYSTEM & FX MENDOZA Item closed
10/05/2017 NPO(HC)-NO VENTILATION MENDOZA Item closed
10/05/2017 NPO - SMOKE ALARMS MENDOZA Item closed
10/05/2017 NPO - EXT. BUILDING MAINTENANC MENDOZA Item closed
10/05/2017 NPO - INT. BUILDING MAINTENANC MENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV03593
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/16/2017 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved KITCHEN SINK FAUCET LEAKS AS WELL HAS THE PLUMBING UNDER THE CABINET. KITCHEN FLOORING IS DAMAGE IN THE CENTER. FRONT BEDROOM FLOOR AT DOORWAY IS DETERIORATED AND SAGS/CREAKS WHEN WEIGHT IS APPLIED. HALLWAY WALL IS DAMAGED/CRACKED. APPEARS TO BE AN OLD REPAIR. SMOKE DETECTOR IN THE HALLWAY IS INOPERABLE. HALLWAY LIGHT IS INOPERABLE. MAIN BATHROOM CEILING IS DETERIORATED DUE TO ROOF DAMAGE. DRYWALL IS CRACKED AND HAS STARTED TO FALL. BATHROOM DOOR HAS A HOLE. REAR BEDROOM CEILING IS DETERIORATED AND HAS BEEN LEAKING A LARGE AMOUNT OF WATER. TENANT IS HAVING TO PLACE LARGE CONTAINERS TO CATCH WATER. AT LEAST 1/4 OR MORE OF THE CEILING IS CRACKED AND SHOWS SIGNS OF WATER DAMAGE. HOLE HAS BEEN CUT IN THE CEILING TO CHANNEL WATER TO ONE LOCATION. CARPORT HAS BEEN WET WITH WATER. NO BLOWER ON SITE TO DRY CARPET. CARPET IS ALSO COVERED IN PEICES OF DRYWALL. MASTER BEDROOM VENTALATION HAS ZERO VOLUME FROM THE COOLING SYSTEM, THOUGH MASTER BATH VENT IS RECEIVING VOLUME. HOLE IN THE BATHROOM DOOR.
10/05/2017 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved ALL DRYWALL DAMAGE REPAIRED. AC VOLUME ISSUE IN THE BEDROOM REPAIRED HALL LIGHT REPAIRED DETERIORATED FLOOR AT EAST BEDROOM DOORWAY REPAIRED. KITCHEN FLOORING REPLACED KITCHEN SINK REPAIRED SMOKE DETECTOR REPLACED BATHROOM DOOR REPAIRED

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T17DV03593
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
08/16/2017 CONTACTED BY MAILING
08/16/2017 NOTICE OF VIOLATION ISSUED
10/05/2017 VIOLATION CLOSED