Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/04/2017

Applicant:

GR PARTNERS SUNFLOWER LLC

Description:

ACTIVE LEAK IN THE LIVING ROOM. ROOF IS CAVING IN

Case Violations

Case Number: T17DV03466
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
08/09/2017 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
08/09/2017 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
08/09/2017 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
08/09/2017 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.
08/09/2017 T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition.

Outstanding Inspections

Case Number: T17DV03466
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
08/21/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX MENDOZA Item closed
08/21/2017 NPO(DL)-DILAPIDATED STRUCTURE MENDOZA Item closed
08/21/2017 NPO - EXT. BUILDING MAINTENANC MENDOZA Item closed
08/21/2017 NPO - INT. BUILDING MAINTENANC MENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV03466
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/09/2017 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved REAR DOOR TO PATIO HAS A LARGE GAP AT THE BOTTOM AND DOES NOT SEAL THE INTERIOR PROPERLY FROM THE ELEMENTS. REAR PORCH DECKING IS DETERIORATED IN THE WEST CORNER. TWO PLANKS WILL REQUIRE REPLACEMENT. ALSO THE DECKING IS NOT SUFFICIENTLY PROTECTED/SEALED FROM THE ELEMENTS. WEST BEDROOM LIGHT SWITCH IS INOPERABLE. ELECTRIAL OUTLETS THROUGHOUT THE UNIT ARE LOOSE, APPLIANCES AND ACCESSORY PLUGS DO NOT PROPERLY SEAT IN THE OUTLETS. THOUGH NOT A VIOLATION AT THE TIME OF INSPECTION, EVIDENCE OF PAST LEAKING IS EVIDENT IN THE LIVING ROOM, LIVING ROOM CLOSET AND IN THE WEST BEDROOM. REPAIRS HAVE BEEN MADE BUT NOT COMPLETED IN A WORKMAN LIKE MANNER. PAINT AND COVERING HAVE BUBBLED OR SAGGED. SOME AREAS ARE LOOSE
08/21/2017 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved CEILING REPAIRS COMPLETE. PATIO DECKING REPAIRED AND SEALED. DOOR SWEEP INSTALLED. LIGHT SWITCH REPAIRED. LOOSE OUTLETS REPLACED.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T17DV03466
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
08/08/2017 CONTACTED BY PHONE
08/09/2017 CONTACTED IN PERSON
08/09/2017 CONTACTED BY MAILING
08/09/2017 CONTACTED BY EMAIL
08/09/2017 NOTICE OF VIOLATION ISSUED
08/21/2017 VIOLATION CLOSED