Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/04/2017

Applicant:

NORTH OF THE RIVER INVESTMENTS LLC

Description:

SINK IS PLUGGED UP. LEAKS IN SINK AND CIELING

Case Violations

Case Number: T17DV03462
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
08/22/2017 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
08/22/2017 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
08/22/2017 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
08/22/2017 T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly.
08/22/2017 T.C. Ch. 16, Sec. 16-13(g)(3) HAZARDOUS POOLS. Any swimming pool or other contained body of water that contains water 18 inches or more in depth at any point and that is wider than 4 feet at any point and is intended for swimming must be properly secured and maintained so as not to create a hazard to public safety, a health hazard or attractive nuisance, and shall be entirely enclosed by a wall, fence or other barrier that is adequate to prevent access by children. Water shall not be allowed to stagnate or to harbor insect infestation.

Outstanding Inspections

Case Number: T17DV03462
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
09/26/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX MENDOZA Item closed
09/26/2017 NPO(PL)-SEWAGE DISPOSAL (SYS) MENDOZA Item closed
09/26/2017 NPO(DL)-DILAPIDATED STRUCTURE MENDOZA Item closed
09/26/2017 NPO - OTHER MENDOZA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV03462
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
08/22/2017 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved BATHTUB FAUCET IS BROKEN AND LEAKING. LACKING A/C FILTER REAR PATIO DOOR DOES NOT SHUT PROPERLY, OR LOCK. SWIMMING POOL HAS AN ACCUMULATION OF TRASH AND STANDING WATER.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T17DV03462
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
08/08/2017 CONTACTED BY PHONE
09/26/2017 CONTACTED IN PERSON
08/22/2017 CONTACTED BY MAILING
08/22/2017 NOTICE OF VIOLATION ISSUED
09/26/2017 VIOLATION CLOSED

Documents

File Name Document Type  
4141E29TH_26NOV1.PDF DOCUMENTS VIEW