Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

07/18/2017

Applicant:

24LIZARDS LLC ATTN: ROBERT LIZARRAGA

Description:

SHUT DOWN. ELEC, PLUMB, ILL DWEL,

Outstanding Inspections

Case Number: T17DV03103
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
07/19/2017 LUC - ILLEGAL DWELLING UNIT MENDOZA Item initialized
07/19/2017 NPO(EL)-MAIN/PANEL/SUB/DISCONT MENDOZA Item initialized
07/19/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX MENDOZA Item initialized
07/19/2017 NPO(PL)-PLUMBING SYSTEM & FX MENDOZA Item initialized
07/19/2017 NPO - SMOKE ALARMS MENDOZA Item initialized
07/19/2017 NPO - EXT. BUILDING MAINTENANC MENDOZA Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV03103
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date Description Inspector Results Comments
07/18/2017 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved TPD CALL OUT. 1. MAIN STRUCTURE HAS HAZARDOUS ELECTRICAL THROUGHOUT THE INTERIOR. TWO BEDROOMS BOTH HAVE ELECTRICAL OUTLETS THAT ARE BROKEN, INOPERABLE, NOT SECURELY ATTACHED AND SHOW SIGNS OF ARCHING AND BURNING. STORAGE AREA BEING UTILIZED AS A DWELLING HAS EXPOSED 22O WIRING THAT IS HANGING WITH NO JUNCTION BOX(WITH ONLY WIRE CAPS). PLASTIC CONDUIT TO PROVIDE OTHER POWER IS NOT SECURELY ATTACH, IS HANGING AND BEING USED TO HANG CLOTHES WHICH HAS BROKEN THE ATTACHMENT ON THE EXTERIOR OF THE ENCLOSURE. OTHER EXPOSED AND NOT SECURED CONDUIT RUNNING THROUGH THE ILLEGAL DWELLING. THREE ADDED WALL A/C UNITS IN EACH BEDROOM AND ILLEGAL DWELLING. 22O CIRCUIT AND ADDED CIRCUITS IN THE ILLEGAL DWELLING. THESE ADDITIONAL CIRCUIRT CAUSING HEAVING TAXING ON DATED 60 AMP SERVICE. DOUBLE LUGGING IN THE MAIN SERVICE PANEL. 2. PLUMBING: MAIN STRUCTURE TOILET IS NOT ATTACHED TO THE FLOOR AND RAW SEWAGE LEAK ON THE FLOOR WHEN FLUSHED. BATHROOM SINK WILL NOT DRAIN. SHOWER FIXTURES ARE BROKEN AND SPRAY WATER WHEN USED. ILLEGAL DWELLING HAS A WATER HEATER INSTALLED WHICH POSES THE THREAT OF CARBON MONOXIDE POISIONING. THE UNIT LACKS TO MEANS OF VENTILATION. 3. UNIT LACKS OPERATIONAL SMOKE DETECTORS. 4. BROKEN WINDOWS IN THE BEDROOMS AND BATHROOM. 5. CARPORT CONVERTED TO STORAGE AND BEING USED AS A DWELLING UNIT. NO WINDOWS OR VENTILATION. HAZARDOUS ELECTRICAL RUNNING THROUGH THE ILLEGAL DWELLING AS WELL AS WATER HEATER POSING A THREAT OF CARBON MONOXIDE. UNIT DEEMED UNFIT TO OCCUPY AND POSTED AS PER DISCUSSION WITH SUPERVISION. TENANTS VACATED. UNIT SECURED BY OWNER. OWNER IN CONTROL OF UNIT.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T17DV03103
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
07/19/2017 CONTACTED IN PERSON
07/19/2017 NOTICE AND ORDER ISSUED
07/19/2017 VIOLATION CLOSED

Documents

File Name Document Type  
508NCHEROKEEADDED220CIRCUIT.JPG IMAGES VIEW
508NCHEROKEEADDED220UNSECUREDSHED.JPG IMAGES VIEW
508NCHEROKEEADDEDACSHED.JPG IMAGES VIEW
508NCHEROKEEADDEDCIRCDBLLUG.JPG IMAGES VIEW
508NCHEROKEEADDEDCIRCUITSSHED.JPG IMAGES VIEW
508NCHEROKEEADDEDELECOUTLETSHED.JPG IMAGES VIEW
508NCHEROKEEBROKENEXTLIGHTFIXTURE.JPG IMAGES VIEW
508NCHEROKEEBROKENINOPOUTLET.JPG IMAGES VIEW
508NCHEROKEEBROKENOUTLET.JPG IMAGES VIEW
508NCHEROKEEBROKENPLUMBINGFIXTURE.JPG IMAGES VIEW
508NCHEROKEEBROKENTOILET.JPG IMAGES VIEW
508NCHEROKEEBROKENUNSECURECONDUIT.JPG IMAGES VIEW
508NCHEROKEEBROKENWINDOW.JPG IMAGES VIEW
508NCHEROKEEBROKENWINDOWAC.JPG IMAGES VIEW
508NCHEROKEEBROKENWINDOWAC2.JPG IMAGES VIEW
508NCHEROKEEILLDWELLING.JPG IMAGES VIEW
508NCHEROKEEPOSTING1.JPG IMAGES VIEW
508NCHEROKEEPOSTING2.JPG IMAGES VIEW
508NCHEROKEEWASHERCONNECTION.JPG IMAGES VIEW
508NCHEROKEEWHINDWELLING.JPG IMAGES VIEW
508NCHEROKEEORDERTOVACATE.PDF DOCUMENTS VIEW
508NCHEROKEEINDEMNIFICATION.PDF DOCUMENTS VIEW