Case: T17DV02042
Case Details
Entered Date:
05/16/2017
Applicant:
EMS REALTY, INC.ATTN ROLAN SETH
Description:
CRACKS IN THE SHOWER FLOOR. nO VETELATION IN BATHROOM AND VENT THAT IS THERE IS BROKEN. HOLES IN THE GARAGE HAVE RODENT PROBLEMS .
Case Violations
Case Number: T17DV02042
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 8
| Violation Date | Code Statue |
|---|---|
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(f)(1) Every wall or vertical support must be sufficient to carry imposed loads safely, and must not lean, buckle, or split due to defect or lack of maintenance. |
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 05/23/2017 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
Outstanding Inspections
Case Number: T17DV02042
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/23/2017 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VALDEZ | Item closed | |
| 08/23/2017 | NPO(PL)-PLUMBING SYSTEM & FX | VALDEZ | Item closed | |
| 08/23/2017 | NPO(DL)-DILAPIDATED STRUCTURE | VALDEZ | Item closed | |
| 08/23/2017 | NPO - INSECTS/PESTS | VALDEZ | Item closed | |
| 08/23/2017 | NPO - SMOKE ALARMS | VALDEZ | Item closed | |
| 08/23/2017 | NPO - EXT. BUILDING MAINTENANC | VALDEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV02042
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/23/2017 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | ONSITE INSPECTION: MISSING SMOKE DETECTORS IN THE HALLWAY. THE FRONT DOOR DEAD BOLT IS NOT PROPERLY ALIGNED. THE MAIN DISCONNECT DEAD FRONT IS NOT INSTALLED. THE DEAD FRONT LACKS LABELING. THE BATHROOM SHOWER STALL HAS CRACKED TILES ON THE SHOWER WALL AND THE FLOOR. THE BATHROOM EXHAUST FAN IS INOPERABLE. THERE ARE SMALL PENETRATIONS IN THE BATHROOM INTERIOR OF THE CABINET. SHOWER STALL LACKS A WATER TIGHT SEAL AROUND THE GLASS BARRIER. THE SHOWER STALL DOOR REQUIRES AN ALIGNMENT. BOTH EXIT DOORS IN THE GARAGE HAVE DAMAGED. THE MAIN GARAGE DOOR IS INOPERABLE. THE FRONT DOOR DEAD BOLT IS NOT PROPERLY ALIGNED. |
| 08/23/2017 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | UNABLE TO CONTACT TENANTS , MANAGEMENT VIA EMAIL STATES ALL VIOLATIONS HAVE BEEN ABATED. CLOSE CASE |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T17DV02042
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 05/17/2017 | CONTACTED BY PHONE |
| 06/14/2017 | RETURNED MAIL |
| 05/24/2017 | CONTACTED BY MAILING |
| 07/20/2017 | CONTACTED BY EMAIL |
| 08/23/2017 | VIOLATION CLOSED |