Case: T17DV01547
Case Details
Entered Date:
04/13/2017
Applicant:
BRIAN BOWERS
Description:
ELECTRICAL ISSUES IN THIS APARTMENT ISSUES OF SPARKING INSIDE WALL LEAKES IN ROOF LIVING ROOM AND BEDROOM, TERMITE ISSUES, AIR. CONDITONER NOT WORKING. STOVE IS HAVING TO BE IGNITED BY LIGHETER SO MAY BE A GAS ISSUE
Case Violations
Case Number: T17DV01547
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 6
Violation Date | Code Statue |
---|---|
04/27/2017 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
04/27/2017 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
04/27/2017 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
04/27/2017 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
06/07/2017 | NOTICE OF VIOLATION ISSUED |
06/07/2017 | VIOLATION CLOSED |
Outstanding Inspections
Case Number: T17DV01547
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
06/06/2017 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | BIGMAN | Item closed | |
06/06/2017 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | BIGMAN | Item closed | |
06/06/2017 | NPO(PL)-GAS SUPPLY/CONNECT | BIGMAN | Item closed | |
06/06/2017 | NPO(PL)-SEWAGE DISPOSAL (SYS) | BIGMAN | Item closed | |
06/06/2017 | NPO(HC)-COOLING | BIGMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV01547
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
04/25/2017 | INSP - INITIAL CODE ENFORCMENT | BIGMAN | Approved | MET WITH OCCUPANT REGARDING COMPLAINT: OUTLETS IN KITCHEN, BATHROOM AND OUTSIDE BY THE FRONT DOOR ARE INOP. CHECKED ELECTRICAL PANEL NO FUSES HAVE BEEN TRIPPED. VENT IN LIVING ROOM HAS FALLEN OUT OF WALL, EXTERIOR DOOR KNOB IS NOT AN EXTERIOR DOOR IT IS AN INTERIOR DOOR KNOB, LONG CRACK IN DRYWALL IN LIVING ROOM. OCCUPANT STATES WATER LEAKS THRU WHEN IT RAINS, NAIL POKING OUT OF THE WALL IN THE DOOR WAY IN BATHROOM. STOVE PIOLT LIGHT MIGHT BE OUT AND NEEDS TO BE RE-LITE. |
06/06/2017 | INSP - FOLLOW UP CODE ENFORCE | BIGMAN | Approved | FOLLOWED UP WITH PROPERTY OWNER AND SENIOR INSPECTOR TO CHECK ELECTRICAL. ELECTRICAL VIOLATION REMOVED WHILE ON SITE. CHECKED DOOR WEATHER STRIPPING. WEATHER STRIPPING INSTALLED. CLOSE CASE. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T17DV01547
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date | Name |
04/18/2017 | CONTACTED IN PERSON |
04/27/2017 | CONTACTED BY MAILING |