RES: MINIMUM HOUSING

Entered Date:

03/14/2017

Applicant:

BRIAN K CAULKINS & PEARL A JT/RS

Description:

LIGHTS IN THE OVEN ARE CONSTANTLY FLICKERING. OUTLET TO THE LEFT OF THE OVEN OUT SPARKS WHEN CONNECTING AN APPLIANCE PLEASE REFER TO EMERGENCY CASE T06VL01249 ELECTRICAL FIRE PLEASE REFER TO PERMIT # T06CM05002 EXPIRED

Outstanding Inspections

Case Number: T17DV01053
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
03/15/2017 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Item closed
03/15/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Item closed

Completed Inspections

Case Status: NOVERIFY
Case Number: T17DV01053
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/15/2017 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Met with the tenant room mate and look at an stove and oven. The light in the over was flickering and move the oven and stove around and all the electrical connection were OK at the outlet. While moving the stove around, the light in the oven was going off at times. Did find where the switch to the light in the over was not getting a good connection due to the over door was not closing properly. The over door was partially opened and not sealed when closed. The door was moving around to the oven and the light would go off and on at times and showed the room mate what was happening. Did check the outlets around the area and all checked OK. Checked the electrical panel on the exterior and found no hot breakers or any breakers tripped. Checked light fixtures and the switches and all were OK. Did let the room mate know that code enforcement does not address appliances as code violation. At this time the room mate has no other issues to look at will be closing the case. Did have Rick Hollander assist on the inspection. Violation Abated, Close Case. RV.
03/15/2017 INSP - INITIAL CODE ENFORCMENT HOLLANDER Approved Assisted Inspector with electrical issues.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T17DV01053
Case Status: NOVERIFY
Total Completed Case Activity Conditions: 1
Date Name
03/30/2017 VIOLATION CLOSED