Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

03/10/2017

Applicant:

K-GAM TRACT C LLC

Description:

ROOF TOP FAN FIRE.

Outstanding Inspections

Case Number: T17DV01009
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
03/13/2017 EMERGENCY CALL OUT GOODMAN Item closed
03/13/2017 NPO - OTHER GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV01009
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
03/10/2017 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD, MANAGER AND PIMA COUNTY HEALTH DEPT. TFD STATED THEY RESPONDED AND FOUND BLOWER THAT REMOVES AIR OUT OF THE HOOD HAD OVERHEATED AND BASICALLY DECINTEGRATED. PIMA COUNTY HEALTH MICHELLE GASHA STATED UPON HER ARRIVAL FOUND THE RESTARAUNT HAD BEEN CLEARED BY TFD, MANAGEMENT HAD ALREADY GOTTEN RID OF ALL FOOD AND WAS CLEANING EQUIPMENT AND KITCHEN AREA AND SHE HAD NO VIOLATIONS. I WALKED UP TO THE ROOF WITH MANAGER SEAN EDWARDS WHO SHOWED ME THE FAN. IN THE AREA WERE TWO LARGE FANS THAT REMOVE HEAT AND SMOKE FROM THE HOOD DOWN BELOW. I INSPECTED THE WORKING UNIT AND DID FIND THE FAN ITSELF IN THE DAMAGED UNIT WAS GONE. POWER FOR THE FAN WAS BUILT IN AND SWITCH TO TURN THE FAN OFF WAS ON THE SIDE OF THE UNIT. MANAGEMENT TURNED THE FAN OFF QUICKLY TO REDUCE AMOUNT OF DAMAGE TO THE FAN AND STATED IT WAS NOT A UNCOMMON OCCURANCE. MANAGEMENT HAD ALREADY CONTACTED ATECH MAINTANENCE AND REPAIR AND SET UP A TIME FOR 7:00 AM THE FOLLOWING DAY TO MAKE REPAIRS DUE TO TEXAS ROAD HOUSE OPENS FOR LUNCH AT 11:00 AM. CALLED AND SPOKE TO MARTIN ROMERO, PASSED ON ALL INFORMATION AND INFORMED HIM C/E HAD NO ISSUES DUE TO EVERYTHING HAVING BEEN TAKEN CARE OF, MARTIN ASKED I FOLLOW UP WITH ATECH TO CONFIRM MAINTANECE GETS COMPLETED. THAT MESSAGE WAS CONFIRMED WITH MANAGEMENT. AT 9:55 AM ON SATURDAY I RECEIVED A CALL FROM BOB BRITTRICH OF ALTECH (SENIOR A MECHANIC) WHO STATED ALL REPAIRS AND THEN SOME HAD BEEN COMPLETED, AND THE HOOD HAD BEEN POWER WASHED TO CLEAR ANY DEBRIS OR POSSIBLE BLOCKAGES. C/E HAS NO FURTHER ISSUES. COMPLIANCE / CLOSE CAS.E

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T17DV01009
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
03/13/2017 CONTACTED BY PHONE