Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T17DV00612
Case Details
Entered Date:
02/10/2017
Applicant:
FOUNDATION FOR HEALTH RESEARCH & PREVENTION
Description:
HAZARDOUS ELECTRICAL
Outstanding Inspections
Case Number: T17DV00612
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/25/2017 | EMERGENCY CALL OUT | GOODMAN | Item closed | |
05/25/2017 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | GOODMAN | Item closed | |
05/25/2017 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | GOODMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV00612
Case Description: EMERGENCY
Total Completed Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/13/2017 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | MET WITH ELECTRICAL CONTRACTOR ANGEL OF ENERGY SOURCE ELECTRIC AND OWNER GLENN H. FOUND ANGEL ALREADY MAKING MINOR REPAIRS IN THE STRUCTURES AND TO THE MAIN SERVICE PANEL I EXPLAINED THE TEP WIRE WAS UNDERSIZED FOR THE PANEL, THE PANEL WAS INSTALLED WITHOUT A PERMIT, PANEL WAS UNDERSIZED FOR TH E COMPLEX AND JUST ABPUT EVERY FUSE IN THE INTERIOR SUB PANELS KEPT POPPING EVIDNENCED BY THE NEW FUSES FOUND THRU OUT THE COMPLEX. I EXPLAINED HE NEEDED TO SPEAK WITH DAN SANTA CRUZ OF CLAYTON TREVILLYAN. ANGEL ASKED IF WE COULD MEET WITH BOTH OF THEM SO ANGEL, MYSELF AND THE OWNER DROVE TO DSD TO SPEAK WITH CLAYTON. DID MEET WITH DAN SANTA CRUZ WHO EXPLAINED BECAUSE OF THE AGE OF THE BUILDING, THE FACT IT WAS COMMERCIAL AND THE VARYING ELECTRICAL PROBLEMS, THAT A ARCHITECT AND ENGINEER WILL PROBABLY NEED TO GET INVOLVED AND DETERMINE LOAD CALCS AS WELL AS CONTACTING TEP TO DETERMINE WHAT WILL WORK, WHAT WON/T AND DAN SUGGESTED THEY GET WITH THE BUILDING OFFICIAL FIRST. CLAYTON WAS NOT IN AT THE TIME, AND ASKED IF THEY COULD WAIT. DAN SUGGESTED THEY MAKE AN APPOINTMENT. |
02/13/2017 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | SUNDAY F/U INSPECTION FOUND ONLY UNIT 11 OCCUPANT ON THE PREMISES, SHE STATED SHE WAS ONLY COMPLETING THE MOVE. |
05/24/2017 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | F/U INPSECTION FOUND ELECTRICAL ISSUES ABATED UNDER PERMIT T17DV01195. COMPLIANCE /CLOSE CASE. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T17DV00612
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date | Name |
03/08/2017 | CONTACTED BY PHONE |
03/08/2017 | CONTACTED IN PERSON |
02/14/2017 | CONTACTED BY MAILING |
03/09/2017 | CONTACTED BY EMAIL |
02/13/2017 | NOTICE OF VIOLATION ISSUED |
05/25/2017 | VIOLATION CLOSED |
02/14/2017 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |