Case: T16DV07639
Case Details
Entered Date:
11/02/2016
Applicant:
RJPH LLC ATTN: JAMES LEBEAU
Description:
no heat unit installed or provided. - swamp cooler/ pump has not worked, pad extremely corroded. - main vertical structure has been highly modified. Potential structural integrity issue. - Ceiling decay/black mold in bedroom from roof leak. - stairs not built to proper dimensions. - stair treads loose/wobbly. - open cavities in kitchen to exterior(old window, east wall connects to roof). - open cavity to adjacent unit, northeast corner of bedroom. - open cavity to adjacent unit (living room), where engineered trusses overlap and pass thru north wall. - open cavities in bedroom (to shop) where roof joist passes through wall. Old pillows stuffed in hole for insulation. - open cavity to - conduit not attached to wall (living room, shop, bedroom). - unknown romex not terminated, not fixed to wall. Exterior, no conduit. - wall ac leaks condensation on electrical outlet below. Has caused excessive decay at floor directly below, also caused drywall to erode allowing junction box/outlet to become unattached from wall. Mold, drywall erosion visible from first floor. - bathroom vents directly to kitchen space. - lights, outlets, junction boxes/ no covers. - old vent pipe terminates open into kitchen space at roof, old paint bucket as a cover at exterior. - fence/wall in back yard unstable. Wood structure badly decayed. - 30 amp outlet hanging from breaker panel via exposed romex. - living room/ multiple holes in wall large enough to fit sharpie marker into that protruded all of the way through wall to exterior. - Rodent infestation.
Outstanding Inspections
Case Number: T16DV07639
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 15
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
| 11/09/2016 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VIDAL | Item closed | |
| 11/09/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VIDAL | Item closed | |
| 11/09/2016 | NPO(PL)-PLUMBING SYSTEM & FX | VIDAL | Item closed | |
| 11/09/2016 | NPO(PL)-GAS SUPPLY/CONNECT | VIDAL | Item closed | |
| 11/09/2016 | NPO(PL)-SEWAGE DISPOSAL (SYS) | VIDAL | Item closed | |
| 11/09/2016 | NPO(PL)-WATER HEATERS | VIDAL | Item closed | |
| 11/09/2016 | NPO(HC)-COOLING | VIDAL | Item closed | |
| 11/09/2016 | NPO(HC)-HEATING & VENTILATION | VIDAL | Item closed | |
| 11/09/2016 | NPO - INSECTS/PESTS | VIDAL | Item closed | |
| 11/09/2016 | NPO - EGRESS | VIDAL | Item closed | |
| 11/09/2016 | NPO - SMOKE ALARMS | VIDAL | Item closed | |
| 11/09/2016 | NPO - OTHER | VIDAL | Item closed | |
| 11/09/2016 | NPO - EXT. BUILDING MAINTENANC | VIDAL | Item closed | |
| 11/09/2016 | NPO - INT. BUILDING MAINTENANC | VIDAL | Item closed |
Completed Inspections
Case Status: NOVERIFY
Case Number: T16DV07639
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/09/2016 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | The unit is vacant and secured. Did call the tenant and left messages and did not return the call. At this time the case will be closed. Has other units next to it and are also vacant and secured. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T16DV07639
Case Status: NOVERIFY
Total Completed Case Activity Conditions: 1
| Date | Name |
| 11/10/2016 | VIOLATION CLOSED |