Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T16DV07365
Case Details
Entered Date:
10/21/2016
Applicant:
TRINITY CHURCH PRESBYTERIAN OF TUCSON
Description:
ILLEGAL LIGHTING INSTALLED ON THE BUILDING WITHOUT PERMIT. EAST SIDE.
Case Violations
Case Number: T16DV07365
Case Status: COMPLIAN
Case Description: LIGHTING VIOLATION
Total Violations: 1
Violation Date | Code Statue |
---|---|
10/21/2016 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T16DV07365
Case Status: COMPLIAN
Case Description: LIGHTING VIOLATION
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/21/2016 | LIGHTING | HOLLANDER | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV07365
Case Description: LIGHTING VIOLATION
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/21/2016 | INSP - INITIAL CODE ENFORCMENT | HOLLANDER | Approved | Two new light installed. HPS or metal Halide. Both are shining above the horizinal for cut off. |
11/21/2016 | INSP - FOLLOW UP CODE ENFORCE | HOLLANDER | Approved | Electrical contractor has adjusted the light fixtures to effectively light the parking for best usage. Complaint is satisfied with the lighting as done. Close case. |
Outstanding Case Activity Conditions
Date | Name | Approved |
10/21/2016 | 2012 Tucson/ Pima County Outdoor Lighting Code Section 104 Permits and Plan Submission Requirements 104.1 Permits required. Any owner or authorized agent who intends to install, construct, enlarge, alter, repair, move, or change any outdoor lighting within Pima County jurisdiction, the installation of which is regulated by this code, shall first make application to the Building Official for Pima County and obtain the required permit. | Not Approved |
10/21/2016 | Section 401 Total Outdoor Light Output and Shielding Requirements 401.1 General. Table 401.1 provides requirements of the total light output permitted per acre for the different lighting areas and the fixture shielding requirements for, lamp type and lighting area. These requirements shall be met for all lighting installations subject to this code, unless specifically exempted by Chapters 6, 7 and 8. 401.3 Shielding requirements. All light fixtures that are required to be shielded shall be installed in such a manner that the shielding is effective and permanent. 401.3.1 Light trespass. Light fixtures on the residential side of commercial property adjacent to residential property shall be full cutoff and shall be installed not higher than 10 feet above grade at the property line and no higher than a line rising 20 degrees above the 10 feet until 100 feet from the property line, measured perpendicular to the lot line. 401.3.2 House Side Shields. Outdoor lighting fixtures closer to the lot line than the mounting height of the fixture, measured perpendicular to the lot line, adjacent to residential areas, shall have internal house-side shields. 401.3.3 Fixtures within 25 feet of residential lot lines. Residential and commercial luminaires shall be full cutoff within 25 feet of adjacent residential property lines, measured perpendicular to the lot line. 401.3.4 Flood and spot lamps. Flood or spot lamps shall be aimed no higher than 45 degrees to the horizontal (half-way between straight down and straight to the side) when the source is visible from any adjacent residential property. | Not Approved |
Completed Activity Special Conditions
Case Description - LIGHTING VIOLATION
Case Number - T16DV07365
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
11/07/2016 | CONTACTED BY PHONE |
10/24/2016 | CONTACTED BY MAILING |
10/21/2016 | NOTICE OF VIOLATION ISSUED |