Case: T16DV05478
Case Details
Entered Date:
09/09/2016
Applicant:
EHLEN FAMILY TRUST/ ATTN: WERTH REALTY
Description:
LEAK IN THE ROOF AND ROOF IS CAVING IN
Case Violations
Case Number: T16DV05478
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
| Violation Date | Code Statue |
|---|---|
| 09/29/2016 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
| 09/29/2016 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 09/30/2016 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T16DV05478
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/15/2016 | NPO(DL)-DILAPIDATED STRUCTURE | GOODMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV05478
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/29/2016 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | UNIT #3251: INSPECTION FOUND A 3FT X 16FT PC OF DRYWALL FALLEN OFF THE LICINGROOM CEILING, AND A 2ND 2 FT X 2FT PC FALLEN CLOSER TO THE KITCHEN AREA. ALSO APPEARED THAT WATER WAS RUNNING INTO THE 3-0 X 3-0 KITCHEN LIGHT AREA EVIDENCED BY THE STAINING ON THE LIGHT GLASS. ALSO A SMALL HOLE IN BATHROOM WALL. UNIT #3253: LEAKS NOT AS BAD AS 3252 BUT FOUND MULTIPLE LEAKS, ONE AROUND THE SUPPLY VENT IN THE KITCHEN, ANOTHER IN THE S/E CORNER OF DINING ROOM, LEAKING AROUND THE KITCHEN WINDOW, BUBBLING IN THE BEDROOM, NORTH WALL, AND AROUND THE BEDROOM WINDOW. CLIMBED UP ONTO THE ROOF. FOUND THE ENTIRE ROOF OVER THE CARPORT AREA TO BE IN BAD CONDITION, ROOF SHEATHING SHOWED FROM UNDERNEATH WATER DAMAGE TO THE SHEATHING EVIDENCED BY PAINT PEELING AND LARGE CRACKS IN THE ROOF SHEATHING. THE ROOF COVERING WAS CRACKED THRU OUT AS WELL AS THE ROOF COATING DETERIORATING AND CRACKING. |
| 12/15/2016 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | FOLLOW UP INSPECTION FOUND A NEW ROOF OVER THE ENTIRE 4-PLEX AND CARPORT AREA. A/C UNITS WERE REMOVED AND REPLACEDNEW A/C MOUNTS ADDED FOR THE A/C UNITS. NEW SKYLIGHT REPLACED OLD ONE OVER THE REAR KITCHEN AREA. INTERIOR DRYWALL HAD BEEN REMOVED AND RPLACED WITH ONE COAT OF TEXTURE, MANAGERS STATED UNITS WILL BE COMPLETED OVER THE WEEKEND. COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T16DV05478
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 09/30/2016 | CONTACTED BY MAILING |
| 09/30/2016 | NOTICE OF VIOLATION ISSUED |
| 12/15/2016 | VIOLATION CLOSED |