Case: T16DV04068
Case Details
Entered Date:
07/05/2016
Applicant:
CONCORDIA RENTALS & PROPERTIES I LLC
Description:
has 2 broken windows, nvn covered electical outlets, and two leaks that are active.
Case Violations
Case Number: T16DV04068
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date | Code Statue |
---|---|
07/08/2016 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
07/08/2016 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
07/08/2016 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
07/08/2016 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
07/08/2016 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
Outstanding Inspections
Case Number: T16DV04068
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
08/22/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | GOODMAN | Item closed | |
08/22/2016 | NPO(PL)-PLUMBING SYSTEM & FX | GOODMAN | Item closed | |
08/22/2016 | NPO(HC)-HEATING & VENTILATION | GOODMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV04068
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/08/2016 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | INSPECTION FOUND THE FOLLOWING ISSUES. >BASEBOARD NOT COMPLETED IN THE BATHROOM >ELECTRICAL OUTLET IN BDRM / NORTH WALL >CRACKED WINDOWS IN BEDROOM AND LIVINGROOM >HOLE IN BDRM CEILING NOT COMPLETED >LEAK IN THE LIVINGROOM CEILING |
08/22/2016 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | FOLLOW UP INSPECTION FOUND UNIT VACANT AND SECURED. CALLED AND SPOKE WITH THE OWNER WHO STATED TENNANT ASKED TO BREAK HER LEASE FOR PERSONAL REASONS AND OWNER DID ALLOW HER TO LEAVE. OWNER STATES ONLY THE CRACKED GLASS IN FRONT WINDOW REMAINS UNFIXED BUT IS NOT A HAZARD. C/E NO LONGER HAS JURISDICTION. COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T16DV04068
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
07/11/2016 | CONTACTED BY MAILING |
07/11/2016 | NOTICE OF VIOLATION ISSUED |
10/13/2016 | VIOLATION CLOSED |