Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

06/21/2016

Applicant:

BUSINESS OWNER: TIM HALARY

Description:

Electrical hazard-work without permit.

Outstanding Inspections

Case Number: T16DV03664
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
08/08/2016 EMERGENCY CALL OUT VALDEZ Extension granted
08/08/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Extension granted
08/08/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Extension granted
08/08/2016 LUC - ZONING OTHER VALDEZ Extension granted
08/08/2016 LUC-NO C OF O VALDEZ Extension granted

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV03664
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/18/2016 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL BY TFD: BUSINESS OWNER WAS WORKING ON HIGH VOLTAGE EQUIPMENT WHILE ENERGIZED AND WAS SHOCKED AND TAKEN TO HOSPITAL, NO VISIBLE SAFETY EQUIPMENT ONSITE. THERE IS FENCED IN AREA INSIDE THE WAREHOUSE WHICH HOUSES 480 VOLTS COMING IN UNDER GROUND TO A LARGE WEATHER HEAD AND DISTRIBUTED TO 3 POT FRONT TRANSFORMERS.. REAR OF THE WEATHER HEAD THERE WAS 3 SMALLER POT TRANSFORMERS WHICH WERE REMOVED AND SET OUTSIDE OF THE FENCED IN AREA. I COULD SEE THE CONCRETE IMPRESSIONS WHERE THE POT TRANSFORMERS USE TO BE. IN THIS AREA OFF THE SIDE THERE HAS BEEN A ((USED)) SQUARE D TYPE INSULATED DRY TYPE TRANSFORMER SERIAL #984417-A1 CLASS AA 3 PHASE 60 HERTZ HV VOLTS 4160 DELTA /// LV VOLTS 208 / 120 INSTALLED WITHOUT PERMITS.. THE BUILDING HAS SEVERAL ELECTRICAL PANELS AND DISCONNECT WITH OPEN OR MISSING COVERS / DEAD FRONTS OR PARTIALLY REMOVED COVERS.. THE UNPERMITTED DRY TRANSFORMER HAS SEVERAL DRILLED HOLES ON THE WEST SIDE OF THE UNIT. THE EASTSIDE OF THE UNIT HAS A ESTIMATE 3 INCH CUT OUT WITH A STEEL PIPE INTENDED TO BE USED AS CONDUIT PIPED TO THE ADJACENT STEEL WALL WHERE THERE IS A GUTTER BOX. INSIDE THE WAREHOUSE THERE IS A 4000 LBS FORK LIFT AND A MQ POWER DIESEL POWERED GENERATOR MODEL MQP240 MODEL DF 3300C 3 PHASE RATED VOLTAGE 240/ 480V SEVERAL BAILS OF HAY. OUTSIDE REAR OF THE BUILDING THERE A LARGE STEEL FRAME HYDRAULIC HAY PRESS SYSTEM, POWER BY THREE LARGE MOTORS THESE MOTOR HAVE A 480V PANEL POWERING EACH MOTOR. THE 3 PANELS CONNECT INTO A GUTTER BOX WITH LARGE CABLES ON THE GROUND. THE AREA HAS TIRE TRACKS FROM THE PORTABLE GENERATOR WHICH I BELIEVE WAS POWERING THE SYSTEM. INSIDE OF THE GUTTER BOX THERE IS AN UNDER RISER WITH NEW CONDUCTORS HANGING OUTSIDE OF THE GUTTER BOX. CITY OF TUCSON ACTIONS AS FOLLOWS: THE BUILDING WAS CONDEMNED AND THE POWER WAS ORDERED SHUT OFF, TEP DID DISCONNECT THE TRANSFORMERS. VIOLATIONS THERE HAS BEEN A NEW HYDRAULIC HAY BAILS PRESS SYSTEM AND NEW ELECTRICAL EQUIPMENT INSTALLED OUTSIDE REAR OF THE BUILDING WITHOUT ZONING APPROVALS AND PERMITS. THE BUILDINGS ELECTRICAL EQUIPMENT IS IN AN UNSAFE MODE. MODIFICATIONS HAVE BEEN DONE TO THE INTERIOR ELECTRICAL EQUIPMENT. INSTALLATION OF A USED TRANSFORMER WAS DONE. ALL THE ABOVE WORK WAS DONE WITHOUT APPROVED ENGINEERED PLANS AND PERMITS FROM THE CITY OF TUCSON. THE BUILDING HAS BEEN OCCUPIED WITHOUT A CERTIFICATE OF OCCUPANCY OR ZONING APPROVALS. THE REQUIREMENTS ARE AS FOLLOWS: A CERTIFICATE OF OCCUPANCY IS REQUIRED. ZONING APPROVAL IS REQUIRED FOR THE CURRENT USE STORAGE OF HAY BAILS IN THE BUILDING ALSO A NEW HAY BAIL PRESS STRUCTURE HAS BEEN INSTALLED AT THE REAR OF THE PROPERTY. AN ELECTRICAL ENGINEER IS REQUIRED
07/27/2016 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT T16CM05478 ISSUED ON 07/27/2016 T16DV03664 - MISC ELECTRICAL UPGRADES; COMM, B.O PLACED A HOLD ON FINAL ELECTRICAL DUE TO ZONING AND A C OF O IS REQUIRED

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T16DV03664
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
06/21/2016 CONTACTED BY PHONE
06/21/2016 CONTACTED IN PERSON
06/22/2016 CONTACTED BY EMAIL
06/21/2016 NOTICE AND ORDER ISSUED
06/20/2017 VIOLATION CLOSED
06/23/2016 RESEARCH
06/21/2016 CALLBACK

Documents

File Name Document Type  
702 E FAIR ST.PDF DOCUMENTS VIEW
20160620_090820.JPG DOCUMENTS VIEW
20160617_164719.JPG DOCUMENTS VIEW
20160617_164727.JPG DOCUMENTS VIEW
20160617_164913.JPG DOCUMENTS VIEW
20160617_165856.JPG DOCUMENTS VIEW
20160617_170121.JPG DOCUMENTS VIEW
20160617_170124.JPG DOCUMENTS VIEW
20160617_170127.JPG DOCUMENTS VIEW
20160617_170214.JPG DOCUMENTS VIEW
20160617_170224.JPG DOCUMENTS VIEW
20160617_170441.JPG DOCUMENTS VIEW
20160617_170607.JPG DOCUMENTS VIEW
20160617_170626.JPG DOCUMENTS VIEW
20160617_170718.JPG DOCUMENTS VIEW
20160617_170733.JPG DOCUMENTS VIEW
20160617_170752.JPG DOCUMENTS VIEW
20160617_171102.JPG DOCUMENTS VIEW
20160617_171132.JPG DOCUMENTS VIEW
20160617_171144.JPG DOCUMENTS VIEW
20160617_171300.JPG DOCUMENTS VIEW
20160617_171310.JPG DOCUMENTS VIEW
20160617_171335.JPG DOCUMENTS VIEW
20160617_171401.JPG DOCUMENTS VIEW
20160617_171411.JPG DOCUMENTS VIEW
20160617_171426.JPG DOCUMENTS VIEW
20160617_172819.JPG DOCUMENTS VIEW
20160617_172831.JPG DOCUMENTS VIEW
20160617_172845.JPG DOCUMENTS VIEW
20160617_173601.JPG DOCUMENTS VIEW
20160617_173757.JPG DOCUMENTS VIEW
20160617_173827.JPG DOCUMENTS VIEW
20160617_173834.JPG DOCUMENTS VIEW
20160617_173848.JPG DOCUMENTS VIEW
20160617_182155.JPG DOCUMENTS VIEW
20160617_182215.JPG DOCUMENTS VIEW
20160617_182348.JPG DOCUMENTS VIEW
20160620_085402.JPG DOCUMENTS VIEW
20160620_085731.JPG DOCUMENTS VIEW
20160620_085742.JPG DOCUMENTS VIEW
20160620_085813.JPG DOCUMENTS VIEW
20160620_085821.JPG DOCUMENTS VIEW
20160620_085832.JPG DOCUMENTS VIEW