Case: T16DV02938
Case Details
Entered Date:
05/12/2016
Applicant:
LYDIA M DELAHANTY 1/3 & MORENO EUGENE C 1/3 & MORENO CECILIA M 1/3
Description:
EMERGENCY FIRE/ DETACHED CARPORT
Outstanding Inspections
Case Number: T16DV02938
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 5
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
11/22/2016 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | GOODMAN | Item closed | |
11/22/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | GOODMAN | Item closed | |
11/22/2016 | NPO(PL)-PLUMBING SYSTEM & FX | GOODMAN | Item closed | |
11/22/2016 | NPO(PL)-GAS SUPPLY/CONNECT | GOODMAN | Item closed | |
11/22/2016 | NPO(DL)-DILAPIDATED STRUCTURE | GOODMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV02938
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/11/2016 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, MET WITH TFD INVETIGATORS AND OWNERS OF THE PROPERTY. FOUND A FIRE HAD STARTED IN THE DETACHED CARPORT/ CONVERTED INTO LIVING SPACEAND COMPLEELY GUTTED BY FIRE. THE UNCLE LIVING N THE CARPORT WAS TRANSFERRED TO THE HOSPITAL BUT OK. TFD DID NOT MAKE DETERMINATION OF HOW THE FIRE STARTED DUE TO THERE BEING TOO MANY VARIABLES: GAS IN A GAS CAN, ELECTRICAL CORD RUNNING FROM HOUSE TO FRYING PAN, FAULTY WIRING/ NOT PROPERLY INSTALLED, MR MORENO FELL ASLEEP WHILE SMOKING. >STRUCTURE WAS A COMPLETE LOSS EXCEPT FOR THE BRICK WALLS. > NO GAS TO THE UNIT/ SW GAS CLEARED THE AREA. >ELECTRICAL 60 AMP SUB PANEL WAS BEING FED FROM A 20 AMP BREAKER IN THE MAIN 200 AMP SERVICE PANEL. >POWER SHUT OFF BY TFD AT THE SERVIVE PANEL >ALL PERSONAL BELONGINGS INSIDE WERE FIRE DAMAGED. >ALL INTERIOR FRAMING AND ROOF FRAMING FIRE DAMAGED >ALL ELECTRICAL AND PLUMBING INSTALLED WITHOUT PERMIT WAS FIRE DAMAGED. >PROPERTY IN A HISTORIC DISTRIST / IS A CONTRIBUTING FACTOR. >NOV'S ISSUED FOR PERMITS REQUIRED AND ELECTRICAL REPAIRS TO THE PANEL. EMERGENCY VACATE NOTICE ISSUED. INDEMNIFICATION ISSUED. >STRUCTURE WAS IN THE REAR YARD BEHIND A 5 FT BLOCK WALL AROUND THE PERIMETER. OWNER CHOOSE NOT TO SECURE THE BUILDING ITSELF. INDEMNIFICATION NOV ISSUED |
11/22/2016 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | INSPECTION FOUND PROPERTY REMAINS CLEAN AND STRUCTURE SECURED. ALL REMINENTS OF THE FIRE HAVE BEEN REMOVED. PERMIT REMAINS IN ISSUED STATUS AFTER OWNERS MEETING WITH HPC. AND STATED THEY DO NOT HAVE MONEY AT THIS TIME TO MOVE FORWARD. SPOKE WITH RICK SALDATE WHO C/E WOULD CLOSE CASE DUE TO NO ACTIVITY. |
Completed Activity Special Conditions
Case Description - RESIDENTIAL FIRE
Case Number - T16DV02938
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
06/20/2016 | CONTACTED BY PHONE |
05/13/2016 | CONTACTED BY MAILING |
11/22/2016 | VIOLATION CLOSED |