Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE
Address:

Entered Date:

04/20/2016

Applicant:

MARY R WILSON

Description:

CARPORT FIRE FOR DUPLEX

Case Violations

Case Number: T16DV02503
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Violations: 1
Violation Date Code Statue
04/20/2016 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T16DV02503
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 6
End Date Description Inspector Results Comments
08/18/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT GOODMAN Item closed
08/18/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Item closed
08/18/2016 NPO(PL)-PLUMBING SYSTEM & FX GOODMAN Item closed
08/18/2016 NPO(PL)-GAS SUPPLY/CONNECT GOODMAN Item closed
08/18/2016 NPO(DL)-DILAPIDATED STRUCTURE GOODMAN Item closed
08/18/2016 NPO - OTHER GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV02503
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
04/20/2016 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved CONTACTED BY COMMUNICATIONS FOR A HOUSE FIRE AT THE ADDRESS. UPON ARRIVAL FOUND 2 ENGINES AND 10 POLICE CARS. I WAS INFORMED BY TFD THAT UPON THEIR ARRIVAL THEY FOUND SEVERAL PEOPLE ARGUING AND GUNS WERE INVOLVED. I ASKED TPD IF I COULD WALK AROUND AND THEY ASKED I WAIT UNTIL ALL PEOPLE INVOLVED HAD BEEN APPREHENDED, THEY WERE STILL LOOKING FOR 2 PEOPLE. TFD HAD ALREADY PUT OUT THE FIRE, MY FINDINGS AREA AS FOLLOWS: >S/W GAS WAS CALLED OUT BY TFD, THERE WAS NO INTERIOR FIRE DAMAGE THEREFORE CONDUCTED A LINE TEST AND MADE THE DECISION TO LEAVE THE GAS ON. >FOUND ONE CAR UNDER THE CARPORT COMPLETELY BURNED AND A SECOND CAR ON THE SOUTH END NEXT TO THE CARPORT PARTIALLY BURNED. CARS WERE TOWED BY TPD. > CARPORT WAS COMPLETELY BURNED. CARPORT SIZE WAS APPROX. 24' X 24', A 3X12 LEDGER BOLTED TO THE WALL, 2X12 RAFTERS 16" OC WERE HUNG FROM THE LEDGER AND SAT ON TOP OF 6"X12" GLU LAM BEAM 14FT FROM THE WALL, THE RAFTERS CANTILEVERED PAST THE BEAM THE REMAINING 10FT >ALSO FOUND ONE FIRE DAMAGED CIRCUIT FOR THE EXTERIOR CARPORT LIGHT.
08/18/2016 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved SPOKE WITH OWNER MARY WILSON WHO STATED SHE HAD NO PLANS TO REBUILD THE PORCH. I ASKED IF SHE COULD REMOVE THE LEDGER FROM THE STRUCTURE AND REMOVE THE 3 METAL POSTS, MARY STATED SHE WOULD HAVE THAT DONE, AND MARY ASKED IF THE FENCE COULD BE REMOVED. THERE IS NO NEED FOR THE FENCE AT THIS TIME. I CONTACTED BIFF BAKER AND ASKED THAT THE FENCING BE REMOVED. COMPLIANCE / CLOSE CASE

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T16DV02503
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
04/25/2016 CONTACTED BY MAILING
04/20/2016 NOTICE OF VIOLATION ISSUED
10/12/2016 VIOLATION CLOSED
05/02/2016 T.C. Ch. 16, Sec. 16-11(f)(1) Every wall or vertical support must be sufficient to carry imposed loads safely, and must not lean, buckle, or split due to defect or lack of maintenance.

Documents

File Name Document Type  
NOV T16DV02503 04-25-16.PDF DOCUMENTS VIEW
DAMAGE REPORT DOC T16DV02503 04-25-16.PDF DOCUMENTS VIEW