Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

03/14/2016

Applicant:

GONZALEZ BALDOMERO & GONZALEZ HIGINIA JT/RS

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T16DV01442
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
06/30/2016 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item closed
06/30/2016 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item closed
06/30/2016 NPO(PL)-GAS SUPPLY/CONNECT VALDEZ Item closed
06/30/2016 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T16DV01442
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
03/13/2016 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: HOUSE FIRE TFD PUNCTURED HOLES AND REMOVED LARGE AMOUNTS OF DRYWALL IN THE CEILING AREA OF ALL THE INTERIOR ROOMS. ABOVE THE KITCHENS ATTIC AREA THERE IS SEVERE DEEP ALLIGATORING TO THE ROOF RAFTERS AND THE ROOF PLANKING, SOME ARE CHARRED. THERE IS A ROOF CUT OUT. THERE IS A 12 X 14 REAR WOOD FRAMED ADDITION ATTACHED TO THE REAR OF THE HOME. THE ADDITION HAS DAMAGE TO MULTIPLE RAFTERS AND THE AREA OF ATTACHMENT TO THE HOME, THIS IS WHERE THE HOME'S TOP PLATE IS BURNT, ESTIMATE 10 FEET OF DAMAGE. THE ADDITION IS NOT BUILT TO CODE. THE KITCHEN HAS AN ENCASEMENT WINDOW WITH TWO PANES BROKEN. THE MAIN DISCONNECT WAS IN CLOSE PROXIMITY TO THE FIRE, THERE ARE CONDUIT RUNS AND BARE WIRING UNDER THE EAVE AREA. THERE IS BARE AND BURNT WIRING IN THE ATTIC AREA. TEP DID REMOVE THE METER AND CUT THE SERVICE DROP AT THE POLE. SWG PINNED THE METER OFF. THE HOME WAS CONDEMNED UNFIT TO OCCUPY DUE TO FIRE DAMAGE. A PLACARD WAS POSTED IN THE FRONT WINDOW. PHOTOS AND REPORTS ARE IN SIRE. SCHEDULE A 60 DAYS FOLLOW UP INSPECTION FOR THE INSPECTOR VALDEZ.
06/30/2016 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PER SUPERVISOR CLOSE CASE

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T16DV01442
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
06/30/2016 CONTACTED BY PHONE
03/14/2016 CONTACTED IN PERSON
03/14/2016 NOTICE AND ORDER ISSUED
06/30/2016 VIOLATION CLOSED
03/14/2016 CALLBACK

Documents

File Name Document Type  
725 W CALLE LERDO.PDF DOCUMENTS VIEW
20160313_060127.JPG DOCUMENTS VIEW
20160313_050717.JPG DOCUMENTS VIEW
20160313_050725.JPG DOCUMENTS VIEW
20160313_050814.JPG DOCUMENTS VIEW
20160313_051409.JPG DOCUMENTS VIEW
20160313_051420.JPG DOCUMENTS VIEW
20160313_051444.JPG DOCUMENTS VIEW
20160313_051600.JPG DOCUMENTS VIEW
20160313_051608.JPG DOCUMENTS VIEW
20160313_052256.JPG DOCUMENTS VIEW
20160313_052302.JPG DOCUMENTS VIEW
20160313_052312.JPG DOCUMENTS VIEW
20160313_052321.JPG DOCUMENTS VIEW
20160313_052332.JPG DOCUMENTS VIEW
20160313_052345.JPG DOCUMENTS VIEW
20160313_052359.JPG DOCUMENTS VIEW
20160313_052718.JPG DOCUMENTS VIEW
20160313_060115.JPG DOCUMENTS VIEW