Case: T16DV00999
Case Details
Entered Date:
02/24/2016
Applicant:
EAST SPEEDWAY PROPERTIES LLC
Description:
LEAK IN THE ROOF, POSSIBLE DILAPIDATED STRUCTURE GOING TO HAPPEN, POSSIBLE ELECTRICAL ISSUES DO TO LEAK.
Case Violations
Case Number: T16DV00999
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 03/14/2016 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 03/14/2016 | UDC, Sec. 10.3.5. VIOLATION OF A SITE PLAN Failure to comply with conditions placed on an approved site plan shall constitute a violation of the UDC. |
Outstanding Inspections
Case Number: T16DV00999
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 04/06/2016 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | NAVARRO | Notice of violation | |
| 04/06/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | NAVARRO | Notice of violation | |
| 04/06/2016 | NPO(PL)-PLUMBING SYSTEM & FX | NAVARRO | Notice of violation | |
| 04/06/2016 | NPO(DL)-DILAPIDATED STRUCTURE | NAVARRO | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV00999
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 03/03/2016 | INSP - INITIAL CODE ENFORCMENT | NAVARRO | Approved | Visited site, inspected, found as follows: 1) no roof leaking 2) four floresent lights with extension cords 3) new window air conditioner installed 4) two doors that are blocked off egress and ingress 5) will research |
| 07/18/2017 | INSP - FOLLOW UP CODE ENFORCE | RSALATE | Approved | 07/18/17: INSPECTOR HAS RETIRED, NO FOLLOW UP CONDUCTED. CASE TO BE CLOSED PER ADMINISTRATOR. INSPECTOR FOUND NO LEAKS ON ROOF AND NO ELECTRICAL THAT CAN BE AFFECTED. EGRESS SHOWS TO DOORS SECTURED BUT HOUSE ONLY REQUIRED TO HAVE ONE EXIT. WILL OPEN CASE AGAIN IF RECIEVE ANOTHER CALL. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T16DV00999
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 03/14/2016 | CONTACTED IN PERSON |
| 04/06/2016 | CONTACTED BY MAILING |
| 03/14/2016 | NOTICE OF VIOLATION ISSUED |
| 07/26/2017 | VIOLATION CLOSED |