Case: T16DV00133
Case Details
Entered Date:
01/11/2016
Applicant:
RAINDROP LLC
Description:
No heat, there is a leak in the roof and it's about to fall.
Case Violations
Case Number: T16DV00133
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 11
Violation Date | Code Statue |
---|---|
01/13/2016 | T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools. |
01/13/2016 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
01/13/2016 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
01/13/2016 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (3) Every habitable room must have at least two electrical receptacle outlets, or one outlet and one electric light fixture. Every bathroom, water closet compartment, and laundry room must have at least one electric light fixture. |
01/13/2016 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
01/13/2016 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
01/13/2016 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
01/13/2016 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
01/13/2016 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
01/13/2016 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
01/13/2016 | T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition. |
Outstanding Inspections
Case Number: T16DV00133
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 12
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
02/19/2016 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VIDAL | Item closed | |
02/19/2016 | NPO(PL)-PLUMBING SYSTEM & FX | VIDAL | Item closed | |
02/19/2016 | NPO(PL)-GAS SUPPLY/CONNECT | VIDAL | Item closed | |
02/19/2016 | NPO(PL)-WATER HEATERS | VIDAL | Item closed | |
02/19/2016 | NPO(HC)-HEATING & VENTILATION | VIDAL | Item closed | |
02/19/2016 | NPO(DL)-DILAPIDATED STRUCTURE | VIDAL | Item closed | |
02/19/2016 | NPO - EGRESS | VIDAL | Item closed | |
02/19/2016 | NPO - SMOKE ALARMS | VIDAL | Item closed | |
02/19/2016 | NPO - OTHER | VIDAL | Item closed | |
02/19/2016 | NPO - EXT. BUILDING MAINTENANC | VIDAL | Item closed | |
02/19/2016 | NPO - WORK WITHOUT PERMIT | VIDAL | Item closed | |
02/19/2016 | NPO - INT. BUILDING MAINTENANC | VIDAL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T16DV00133
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
01/11/2016 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Received call from Rick Mendoza that unit has no heat and roof leaking. Arrived and Southwest gas was on site checking the gas air furnace and the water heater. Met with the tenant and they have just came out of the hospital due to illness. The tech for Southwest gas was in the process for checking for carbon monoixde due to the tenant called due to the illness the tenant had and being in the hospital. The furnace was working which the tenant has not been using at this time. The water heater has been replaced which appears in 2012. The gas line has not been corrected with the sediment trap, the flex line is the existing, and the valve is existing. It appears no permit was issued for the installation of the water heater replacement. The ceiling in the hallway has fallen leaving a hole in the drywall. No smoke detectors in the hallway or the bedrooms. The roof appears to be leaking and went on the roof and the roof has been patched several times in different areas. The roof appears to need to be coated due to bear spots through out the roof. The kitchen outlet is lacking the GFCI outlet with the bathroom outlets being on a breaker for GFCI. The toilet is flushing slow and having trouble with the drainage. The sliding glass door is not sealed in the middle and appears to be the wrong panel to match the fixed panel and not meeting in the middle to have the proper seal. The windows had screws to prevent the windows to open with some of the screws removed with the windows hard to open. The closet in the master bedroom is currently not being used due to the roof leaks and smells. Will have to check for the permit on the water heater. The CO levels are OK with the testing of Southwest gas and met with the tenants to go over that it's OK to stay in the unit. Did go over that if they fill sick or get headaches to call 911 to have the fire department come to the property and will check the levels and they will call us back to check the property. Did get the phone number to call the owner and the maintenance to go over what is needed to be addressed on the property. Will do N.O.V. RV. |
02/19/2016 | INSP - FOLLOW UP CODE ENFORCE | VIDAL | Approved | The owner and the tenant are meeting and getting issues resolved. At this time the case will be closed due to issues that were a complaint have been abated. Owner out of state and has a maintenance man in Tucson that does the work. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T16DV00133
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
01/13/2016 | CONTACTED BY PHONE |
01/20/2016 | CONTACTED BY MAILING |
01/20/2016 | CONTACTED BY EMAIL |
01/20/2016 | NOTICE OF VIOLATION ISSUED |
11/15/2016 | VIOLATION CLOSED |