Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/10/2015

Applicant:

CONREW LLC ATTN: MARGEAUX BOWERS

Description:

HOLE IN THE FRONT DOOR WHERE YOU CAN PUT YOUR HAND THROUGH, ELECTRICAL OUTLETS DONT HAVE COVERS, LEAK IN THE CEILING, LEAK IN THE KITCHEN SINK.

Case Violations

Case Number: T15DV09532
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
01/04/2016 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
01/04/2016 T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room.
01/04/2016 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.

Outstanding Inspections

Case Number: T15DV09532
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
12/31/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX BIGMAN Notice of violation
12/31/2015 NPO(PL)-PLUMBING SYSTEM & FX BIGMAN Notice of violation
12/31/2015 NPO - OTHER BIGMAN Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV09532
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/31/2015 INSP - INITIAL CODE ENFORCMENT BIGMAN Approved LEAK UNDERNEATH THE KITCHEN SINK, (2) KITCHEN OUTLET COVER MISSING, (1) BEDROOM LIGHT SWITCH COVER MISSING, VENT IN BATHROOM DOES NOT WORK, LEAK IN THE CEILING ABOVE THE TOILET. MET WITH PROPERTY MANAGER B.B. HE STATED HE WOULD ADDRESS ALL THE VIOLATIONS. WILL MAIL OUT AN NOV.
02/05/2016 INSP - FOLLOW UP CODE ENFORCE BIGMAN Approved OUTLET COVERS INSTALLED, LIGHT SWITCH COVER INSTALLED, VENT VIXED, KITCHEN AND BATHROOM SINK FIXED. CLOSE CASE.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV09532
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
01/15/2016 CONTACTED BY MAILING
01/15/2016 NOTICE OF VIOLATION ISSUED
02/25/2016 VIOLATION CLOSED

Documents

File Name Document Type  
NOV_9532.PDF DOCUMENTS VIEW