Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/04/2015

Applicant:

MALGORZATA PRUSIEWICZ

Description:

Roof damaged and has cracks one inch and a half. Wall has cracks and window gaps.Kitchen ceiling collapsing and bowed.Walls bowing. Back side of trailer-supporting beams sinking and dilapidated. Sewer line to low and backs up the plumbing. Floors rotten in the bathroom.

Case Violations

Case Number: T15DV09398
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
Violation Date Code Statue
12/10/2015 T.C. Ch. 16, Sec. 16-12(b)(2) WALLS. Exterior walls shall be maintained in a sound condition that is substantially weathertight and weatherproof, and shall be protected from the elements by paint or other approved protective covering. Exterior walls must be free of loose, crumbling or deteriorated plaster or rotted, split or buckled exterior wall coverings.
12/10/2015 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
12/10/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
12/11/2015 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T15DV09398
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
12/04/2015 NPO(DL)-DILAPIDATED STRUCTURE CAMACHO Item initialized
12/04/2015 NPO - EXT. HAZ/ATTRACT NUISANC CAMACHO Item initialized
12/04/2015 NPO - EXT. BUILDING MAINTENANC CAMACHO Item initialized
12/04/2015 NPO - INT. BUILDING MAINTENANC CAMACHO Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV09398
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 3
End Date Description Inspector Results Comments
12/04/2015 INSP - INITIAL CODE ENFORCMENT MMENDOZA Approved Inspected trailer and found strong evidence of roof leaking and multiple walls in a dilapidated and water damage state, south wall and floor sagging. possible electrical damage in walls from water leaks, tenants claims of electrical shocks, exposed romex and inproperly sized for dryer circuit.
02/16/2016 INSP - FOLLOW UP CODE ENFORCE MMENDOZA Approved Met with manager on site , all repaires to inside and outside of trailer completed, empty unit , violations abated-CLOSE CASE
02/16/2016 INSP - FOLLOW UP CODE ENFORCE MMENDOZA Approved Met with manager on site , interior of trailer remodeled and rebuilt. work still in progress. granted extension 3/18/16

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV09398
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
12/14/2015 CONTACTED BY MAILING
12/14/2015 NOTICE OF VIOLATION ISSUED
03/04/2016 VIOLATION CLOSED