Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

CAR THROUGH COMMERCIAL BUILDIN
Address:

Entered Date:

12/04/2015

Applicant:

PALOMA APARTMENTS LLC

Description:

CAR INTO COMMERCIAL BUILDING

Outstanding Inspections

Case Number: T15DV09357
Case Status: COMPLIAN
Case Description: CAR THROUGH COMMERCIAL BUILDIN
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
12/03/2015 NPO(DL)-DILAPIDATED STRUCTURE CAMACHO Item initialized
12/03/2015 NPO - EXT. HAZ/ATTRACT NUISANC CAMACHO Item initialized
12/03/2015 NPO - WORK WITHOUT PERMIT CAMACHO Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV09357
Case Description: CAR THROUGH COMMERCIAL BUILDIN
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/03/2015 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE MET WITH TFD OFFICERS AND OWNER OF THE APT. COMPLEX PAUL KAHN. VEHICLE RAN INTO THE SOUTH WALL OF APT #21 DAMAGING THE BLOCK/FURR OUT WALL, RIGHT BELOW A 4-0 X 4-0 BEDROOM WINDOW, THERE WERE NO OCCUPANTS HOME AT THE TIME. OWNER AND ON SITE MANAGER RICK MARTIN TURNED OFF POWER TO THE UNIT FROM THE SUB PANEL INSIDE THE 2ND BEDROOM THAT WAS NOT DAMAGED. OWNER HAD SPOKEN TO TENNANT ARACELY VALENCIA AND INFORMED HER OF THE ACCIDENT AND INFORMED HER HE HAD TWO VACANT UNITS THAT SHE COULD CHOOSE FROM, UNITS 18 OR 11 AND MAINTANENECE PERSON RICK MARTIN WOULD BE AT HER DISPOSAL TO HELP MOVE. MY FINDING TO THE DAMAGED BUILDING ARE AS FOLLOWS: >EXTERIOR BRICK DAMAGED ABOVE, BELOW, AND AROUND THE WINDOW AREA LEAVING A HOLE APPROX. 8 FT X 8 FT. LINTEL ABOVE THE WINDOW NEEDED TO BE SHORED UP. > 2 X 4 FRAME FURRED OUT WALL WAS ALSO DAMAGED, KING STUDS AND WINDOW TRIMMERS CRACKED IN HALF, CRIPPLES AND SILL PLATE DAMAGED AND FORCED INTO THE BEROOM AREA. > DRYWALL DAMAGE TO MOST OF THE SOUTH BEDROOM WALL AND SOME DAMAGE TO THE CEILING. >ELECTRICAL WIRING WAS STRETCHED FROM EAST TO WEST OUTLET ON THE SOUTH WALL AND OUTLETS DAMAGED. POWER TURNED OFF AT THE SUB PANEL AND REMAINS OFF AT THIS TIME. EMERGENCY VACATE NO ISSUES, PERMITS REQUIRED NOV ISSUED, AND INDEMNIFICATION NOTICE ISSUED DUE TO OCCUPANTS QUICKLY REMOVING BELONGINGS INTO UNIT # 18, DOWN AND ACROSS THE WALKWAY. ALL PAPERWORK SIGNED FOR BY OWNER PAUL KAHN. MAINTANENECE AND OWNER VERY HELPFUL THROUGHOUT THE SITUATION. OWNER ASKED THAT THE CITY SECURE THE OPENING, DAMIEN USED TWO FULL SHEETS OF PLYWOOD TO SECURE THE OPENING AND ONE 2X4 TO SHORE UP THE LINTAL, ONCE THE OCCUPANT HAD REMOVED ALL BELONGINGS, OWNER WILL CHANGE THE LOCKS.
05/16/2016 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved ALL WORK COMPLETED UNDER PERMIT T15CMO8520. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - CAR THROUGH COMMERCIAL BUILDIN
Case Number - T15DV09357
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
12/04/2015 CONTACTED IN PERSON
12/04/2015 CONTACTED BY MAILING
12/04/2015 NOTICE AND ORDER ISSUED
12/04/2015 NOTICE OF VIOLATION ISSUED
11/08/2016 VIOLATION CLOSED
03/31/2016 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
01/14/2016 STRUCTURE SECURED BY ???

Documents

File Name Document Type  
09357.PDF DOCUMENTS VIEW