Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

12/01/2015

Applicant:

BRIAN BOWERS

Description:

No heat all winter, elect outlet shorting and without covers, window broken in bedroom

Case Violations

Case Number: T15DV09245
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date Code Statue
12/02/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
12/02/2015 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
12/02/2015 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
12/02/2015 T.C. Ch. 16, Sec. 16-12(a)(3) BOARDED WINDOW OR DOOR OPENINGS. a. No occupied structure may have boarded window or door openings, except as necessary on a temporary basis to keep the structure secure while under repair. b. While vacant structures may temporarily be secured by boarding up window and door openings in accordance with section 16-14(b), having or maintaining boarded window or door openings on a vacant structure for 180 days or more in any one-year period is prohibited.
12/02/2015 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T15DV09245
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
12/02/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT BIGMAN Follow-up inspection
12/02/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX BIGMAN Follow-up inspection
12/02/2015 NPO(HC)-HEATING & VENTILATION BIGMAN Follow-up inspection
12/02/2015 NPO - OTHER BIGMAN Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV09245
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
12/02/2015 INSP - FOLLOW UP CODE ENFORCE BIGMAN Approved RESEARCH: CK P+ FOR PERMITS. FOUND PERMITS FOR ELECTRICAL UPGRADE ON BOTH UNITS 2 & 12. BOTH PERMITS WERE FINALED.
12/02/2015 INSP - INITIAL CODE ENFORCMENT BIGMAN Approved INSPECT UNIT #2 & #12 LACK OF HEATING. UNIT #2: NORTH BEDROOM HAS A BROKEN WINDOW AND A LEAK IN THE CEILING, HOLES IN THE WALL IN THE BATHROOM & BEDROOM, LARGE WALL SIZE MIRROR HAS A VERY LARGE CRACK (MIRROR NEEDS TO BE COMPLETELY REMOVED), WEATHER STRIPPING AT FRONT DOOR MISSING, BATHROOM DOOR OFF HINGE, EXTERIOR WALL NEXT TO BEDROOM ON NORTH SIDE OF UNIT HAS A HOLE IN THE WALL AND SEVERAL BLOCKS MISSING AROUND THE WINDOW AREA, OUTLET COVERS MISSING IN BATHROOM AND BEDROOM. 2 WIRE SYSTEM HAS THREE WIRE OUTLETS INSIDE UNIT, LIGHT GLOBE MISING IN KITCHEN AND BATHROOM, OUTLET IN KITCHEN BEHIND REFRIGERATOR HAS A SHORT, DISCONNECT BOX NEEDS TO BE LABELED, LEAK UNDER KITCHEN SINK, KITCHEN CABINETS ARE MISSING PARTS OF THE CABINTRY. UNIT #12: NO HEATING COMPLAINT.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV09245
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
12/10/2015 CONTACTED BY MAILING
12/10/2015 NOTICE OF VIOLATION ISSUED
07/20/2016 VIOLATION CLOSED

Documents

File Name Document Type  
NOV_9245.PDF DOCUMENTS VIEW