Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

11/09/2015

Applicant:

ESTRELLA 10 PROPERTIES LLC

Description:

KITCHEN FIRE

Case Violations

Case Number: T15DV08641
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Violations: 4
Violation Date Code Statue
11/09/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
11/09/2015 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
11/09/2015 T.C. Ch. 16, Sec. 16-11(g) INTERIOR SANITATION. (1) The interior of every building or structure shall be maintained free from any unsafe or unsanitary accumulation of refuse. (2) All sanitary facilities shall be installed and maintained in a safe and sanitary condition. (3) Every dwelling unit must have a kitchen, which shall include a sink. Sink drain boards and countertops adjacent to the kitchen sink shall be made of non-absorbent materials, or must be covered by a non-absorbent material.
11/09/2015 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (4) All plumbing fixtures shall be connected to a public sewer system or to an approved private sewage disposal system, with the connections free from leaks, blockages, or other defects. All plumbing fixtures shall be connected to an approved system of water supply and provided with hot and cold running water necessary for its normal operation.

Outstanding Inspections

Case Number: T15DV08641
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
11/08/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT CAMACHO Item initialized
11/08/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX CAMACHO Item initialized
11/08/2015 NPO(PL)-PLUMBING SYSTEM & FX CAMACHO Item initialized
11/08/2015 NPO - OTHER CAMACHO Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV08641
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/08/2015 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATORS, S/W GAS WAS ONSITE TESTING GAS LINES AND POWER HAD BEEN TURNED OFF AT THE SERVICE PANEL BY TFD. TFD HAD PROPERTY MANAGER INFO AND I OBTAINED THE OWNER INFO FROM TEP. OWNER LIVES IN HUNNINGTON BEACH CA, NO CONTACT NUMBERS WERE GIVEN. NEIGHBORS STATED THEY DID NOT THINK ANYONE WAS SUPPOSE TO BE LIVING THERE ALTHOUGH THEY DID SEE 3 PEOPLE POSSIBLY MOVING IN ON FRIDAY 10/06, BUT SAW NO ONE THERE AFTER FRIDAY. SUNDAY EVENING THEY HEARD THE SMOKE ALARMS, SAW FIRE FROM THE WINDOW AND CALLED TFD. FINDINGS ARE AS FOLLOWS: >FOUND WAX FROM A TALL CANDLE THAT HAD MELTED ALL OVER THE COUNTER AND BURNED APPROX 2' X 2' OF THE COUNTER TOP. > DIRECTLY ABOVE THE COUNTER AND CANDLE WAS A SWITCH THAT HAD ALSO MELTED AND SURROUNDING DRYWALL DAMAGED AND WALL OPENED BY TFD. > FOUND MINOR SMOKE DAMAGE IN THE LIVINGROOM/ DINING ROOM AREA, AND THE WOOD CEILING AND BEAMS IN THE KITCHEN AREA RECEIVED HEAVY SMOKE DAMAGE. >FOUND WATER CLOSET FOR THE HOT WATER HEATER ROOM IN THE BATHROOM AND S/W GAS FOUND SEVERAL ISSUES WRONG WITH THE HOTWATER HEATER ITSELF AND LEFT GAS OFF TO THE WATER HEATER. I CLOSED THE WINDOWS AND LOCKED AND CLOSED THE DOORS BEHIND ME. WILL TRY TO CONTACT THE PROPERTY MANAGER ON MONDAY 10/09. WILL MOVE FORWARD WITH THE NOTICE OF VIOLATION.
03/18/2016 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved FOLLOW UP INSPECTION FOUND FRONT DOOR MOLIND AND DOOR JAMB REPLACED AND NEW SIDE DOOR INSTALLED. CABINETS HAD BEEN REPAIRED AND COUNTERTOPS TOTALLY REPLACED. A NEW OUTLET AND WIRING HAD BEEN INSTALLED FOR THE FIRE DAMAGED OUTLET. INTHE BATHROOM THE HOTWATER HEATER SOUTH WALL WAS FILLED IN AND DRYWALLED AND DOOR PLACED IN THE HALLWAY. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T15DV08641
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
11/13/2015 CONTACTED IN PERSON
11/13/2015 CONTACTED BY MAILING
11/13/2015 NOTICE OF VIOLATION ISSUED
11/08/2016 VIOLATION CLOSED

Documents

File Name Document Type  
08641.PDF DOCUMENTS VIEW
2937 N. ESTRELLA EMERGENCY CALL OUT.PDF DOCUMENTS VIEW