Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

10/27/2015

Applicant:

JOSE J & ROSA D MONTANO JT/RS

Description:

DUPLEX FIRE

Outstanding Inspections

Case Number: T15DV08203
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
10/27/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item initialized
10/27/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item initialized
10/27/2015 NPO(PL)-GAS SUPPLY/CONNECT VALDEZ Item initialized
10/27/2015 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV08203
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/26/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY: TFD THERE WAS A FIRE IN A DUPLEX UNIT 120 WAS DAMAGED BY FIRE, THE BEDROOM SUSTAINED THE MOST DAMAGE THERE IS DAMAGE TO AN AREA OF 18 FEET LONG TO THE ROOF EAVE AREA AND ALSO TO THE 11 TRUSSES, TWO THE TRUSSES ARE DAMAGE IN THE BEDROOM INTERIOR. THERE IS A 2 FOOT BY A 3 FOOT ROOF CUT OUT. THERE IS INTERIOR DAMAGE TO THE BEDROOM'S DRYWALL IN THE CEILING AND THE WALLS TO INCLUDE THE EXIT DOUBLE SLIDER. THE KITCHEN, BATHROOM AND SECOND BEDROOM HAVE INSPECTION HOLES IN THE CEILING DRYWALL IN SOME AREAS THE WALLS ARE DAMAGED. THE KITCHEN HAS A BROKEN WINDOW. ALL OF THE DWELLING WINDOWS HAVE GRATES. THE HOME RUNS TO UNITS 120 AND 122 ARE IN THE ATTIC AREA WHICH ARE IN THE FIRE ZONE ABOVE THE BEDROOM. THERE ARE SOME CONDUCTORS WHICH ARE BARE AND THERE ARE LIGHT FIXTURES AND ELECTRICAL DEVICES IN THE INTERIOR THAT HAVE MELTED AND HAVE HEAT DAMAGE.. TEP DID BOOT BOTH METERS OFF. THE GAS LINES ARE ALSO IN THE SAME LOCATION, SWG DID PIN BOTH METERS OFF. BOTH UNITS WERE CONDEMNED UNSAFE TO OCCUPY. 122 W NEBRASKA WAS CONDEMNED DUE TO ALL HOME RUNS WERE IN THE FIRE ZONE IN THE ATTIC AREA LOCATED AT 120 W NEBRASKE ST.SCHEDULE A 30 DAY FOLLOW UP INSPECTION..
03/22/2016 INSP - FOLLOW UP CODE ENFORCE MMENDOZA Approved PERMITS T15CM08866 , T15OT01683 IN ISSUED STATUS-violation abated-CLOSE CASE

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T15DV08203
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
10/27/2015 CONTACTED IN PERSON
10/27/2015 NOTICE AND ORDER ISSUED
03/23/2016 VIOLATION CLOSED
12/04/2015 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
10/27/2015 STRUCTURE SECURED BY ???
10/27/2015 CALLBACK

Documents

File Name Document Type  
120 W NEBRASKA ST.PDF DOCUMENTS VIEW
20151026_231538.JPG DOCUMENTS VIEW
20151026_220930.JPG DOCUMENTS VIEW
20151026_220943.JPG DOCUMENTS VIEW
20151026_221924.JPG DOCUMENTS VIEW
20151026_221929.JPG DOCUMENTS VIEW
20151026_221945.JPG DOCUMENTS VIEW
20151026_221956.JPG DOCUMENTS VIEW
20151026_222000.JPG DOCUMENTS VIEW
20151026_222116.JPG DOCUMENTS VIEW
20151026_222447.JPG DOCUMENTS VIEW
20151026_223423.JPG DOCUMENTS VIEW
20151026_223431.JPG DOCUMENTS VIEW
20151026_231523.JPG DOCUMENTS VIEW