Case: T15DV07729
Case Details
Entered Date:
10/09/2015
Applicant:
RODRIGUEZ ERNEST E & CELIA C
Description:
ROOF DAMAGE
Case Violations
Case Number: T15DV07729
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 11/03/2015 | T.C. Ch. 16, Sec. 16-13(g)(1) ABANDONED REFRIGERATORS. All premises shall be kept free of iceboxes, refrigerators or other containers with a capacity of one and one-half (1 ½ ) cubic feet or greater that have an attached door or lid, snaplock or other locking device that may not be released from the inside and that are abandoned, discarded or no longer used for refrigeration and are in any place accessible to children. In addition to any other remedy provided under this chapter, a code official may immediately and without prior notice remove an attached door, lid or other locking device or take other similar action to abate the hazard presented. |
| 10/09/2015 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
Outstanding Inspections
Case Number: T15DV07729
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/09/2015 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VALDEZ | Item initialized | |
| 10/09/2015 | NPO(DL)-DILAPIDATED STRUCTURE | VALDEZ | Item initialized |
Completed Inspections
Case Status: COMPLIAN
Case Number: T15DV07729
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/07/2015 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TPD: ONSITE INSPECTION RESULTS, THE CARPORT AREA THAT WAS CONVERTER INTO LIVING SPACE HAS ROOF DAMAGE FROM WATER INTRUSION, THERE ARE SEVERAL ROOF RAFTERS AND ROOF SHEATHING THAT ARE DETERIORATE. THERE IS DEFECTION IN THE CENTER OF THE ROOF. A 12' X 4' SECTION OF CEILING MATERIAL WHICH IS PLASTER HAS COLLAPSED. THERE IS ANOTHER SECTION OF CEILING PLASTER THAT A PORTION HAS DETACHED FROM THE ROOF RAFTERS AND IS CAUSING STRAIN ON THE ATTACHED PLASTER. THERE ARE 3 ROOF RAFTERS THAT ARE NO LONG BEARING ON THE EXTERIOR WALL. THE AREA OF CONCERN IS ESTIMATED AT 13.6 X 21. SUPERVISOR AUTHORIZED A TEMPORARY STABILIZATION OF 5 ROOF RAFTERS IN ORDER TO MAINTAIN THE ROOF LOAD AND SUPPORT OF THE ROOF ASSEMBLY. THE POWER IS OFF THE THIS AREA. ONE CEILING LIGHT FIXTURE NEEDS TO BE REMOVED. MORNING INSPECTION REQUIRED. |
| 10/08/2015 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ONSITE INSPECTION: THE ENTIRE CEILING WHICH IS PLASTER HAS BEEN REMOVED. THE LIGHT FIXTURE HAS BEEN REMOVED, THE 2X6 RAFTERS ARE ATTACHED TO THE MAIN DWELLINGS FASCIA. THE RAFTERS ARE UNDER SIZED THE REST OF ROOF MEMBERS TO INCLUDE THE RAFTERS ARE DETERIORATED AND NO LONGER ABLE TO SUPPORT THE ROOF LOAD OR KEEP THE WEATHER ELEMENTS FROM ENTERING INTO THE INTERIOR. THERE IS DEFECTION IN THE CENTER OF THE ROOF. OCCUPANCY CONTINUES UNDER THE CONDITIONS OF THE NOTICE OF VIOLATION.A NOTICE OF VIOLATION WILL BE ISSUED FOR THE REMOVAL OF THE ROOF ASSEMBLY. |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 10/09/2015 | TC CHAPTER 16 SEC 16-65 ABATEMENT BY DEMOLITION SHALL BE ORDERED ONLY WHERE REPAIR OF THE STRUCTURE IS UNREASONABLE OR IMPRACTICABLE, AND DEMOLITION AND REMOVAL OF A STRUCTURE OR BUILDING IS NECESSARY TO CORRECT AND ABATE A VIOLATION. ANY ACTION INVOLVING THE DEMOLITION OF A BUILDING OR STRUCTURE SHALL BE COMMENCED BY ISSUING A NOTICE OF VIOLATION TO THE OWNER AND ANY RESPONSIBLE PARTIES IN ACCORDANCE WITH THE PROVISIONS OF SECTION 16-45. | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T15DV07729
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
| Date | Name |
| 10/09/2015 | CONTACTED BY PHONE |
| 10/09/2015 | CONTACTED IN PERSON |
| 10/12/2015 | CONTACTED BY MAILING |
| 10/09/2015 | NOTICE AND ORDER ISSUED |
| 01/11/2016 | VIOLATION CLOSED |
| 11/03/2015 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |
| 10/09/2015 | STRUCTURE SECURED BY ??? |
| 10/09/2015 | CALLBACK |