Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

09/21/2015

Applicant:

OLGA LOPEZ

Description:

HOUSE FIRE (F152640082)

Outstanding Inspections

Case Number: T15DV06953
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
09/21/2015 NPO(DL)-DILAPIDATED STRUCTURE BARRON Item initialized
09/21/2015 NPO - OTHER BARRON Item initialized
09/21/2015 NPO - WORK WITHOUT PERMIT CAMACHO Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV06953
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/21/2015 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATOR WAYNE CUMMINGS, WAYNE STATED TFD HAD TURNED POWER OF AT THE MAIN SERVICE PANEL AND TEP WAS IN ROUTE. S/ W GAS WAS ON SITE, BUT IN THE PROCESS OF CONDUCTING LINE TEST. FIRE FIGHTERS WERE IN THE PROCESS OF PULLING PERSONAL BELONGINGS OFF THE SHELVES CHECKING FOR HOT SPOTS, NEEDED TO GAIN ENTRY. DID FIND THAT THE FIRE WAS LIMITED TO THE GARAGE AND LAUNDRY ROOM THAT WAS ENTERED FROM THE GARAGE AND YOU PASS THRU THE LAUNDRY ROOM TO ENTER THE CARPORT. ENTERED THE HOUSE WITH TFD INVESTIGATOR, FOUND FROM THE LAUNDRY ROOM YOU ENTER A SMALL HALLWAY AND OFF THE HALLWAY WERE TWO (KIDS) BEDROOMS, THE MASTER BEDROOM AND THE BATHROOM. ALL DOORS HAD BEEN CLOSED AND FOUND ONLY VERY MINOR SMOKE DAMAGE. I ALSO CHECKED THE LIVINGROOM AND KITCHEN/DININGROOM AND AGAIN FOUND ONLY MINOR SMOKE DAMAGE. >MET WITH TEP AND A DECISION WAS MADE TO BOOT THE METER. >S/ W GAS CONDUCTED THE EXTERIOR LINE TEST WHICH CHECKED OUT OK. ONLY THE HOTWATER HEATER WAS GAS AND PRESSURE TEST ON THE INTERIOR LINE FOUND NO LEAKS. GAS METER WAS SHUT OFF AND PINNED. >TFD DETERMINED FIRE STARTED FROM PAPER PRODUCTS AROUND THE HOTWATER HEATER IN THE GARAGE. ONE VEHICLE WAS LEFT IN THE GARAGE AND RECEIVED FIRE DAMAGE. >GARAGE DRYWALL APPEARED TO HAVE A LAYER OF 1/4" DRYWALL OVER A LAYER OF 1/2 FIRE RATED DRYWALL. ALL DRYWALL RECEIVED FIRE DAMAGE. FIRE DID NOT MOVE INTO THE ATTIC SPACE. I COULD ONLY SEE INTO ATTIC THRU SMALL HOLES IN THE CEILING DRYWALL FROM TFD AND FROM THE HOLES COULD NOT SEE ANY DAMAGE TO THE TRUSSES OR THE ROOF SHEATHING. >HOT WATER HEATER AND ALL PLUMBING FIXTURES WERE FIRE DAMAGED. > A/C UNIT NEXT TO THE HOTWATER HEATER WAS FIRE DAMAGED. >PLENNUM ATHAT BOTH THE HOT WATER HEATER AND THE A/C UNIT SAT ON WAS THE ONLY FRAMING THAT WAS FIRE DAMAGED. >ELECTRICAL OUTLETS AND SWITCHES, GARAGE DOOR OPENER, AND ELECETRICAL FOR THE A/C WAS ALL FIRE DAMAGED. >DRYWALL IN THE WASHER/DRYER ROOM ALSO FIRE DAMAGED. NOV FOR EMERGENCY VACATE WAS ISSUED DUE TO LACK OF UTILITIES. NOV FOR ALL REPAIRS TO FIRE DAMAGED PORTIONS OF THE STRUCTURE WAS ALSO ISSUED AND INDMENIFICATION WAS ALSO ISSUED DUE TO ALL THE PERSONAL BELONGINGS AND CAR FIRE DAMAGED IN THE GARAGE, AND ALLTHE DIFFERENT PEOPLE IN AND OUT OF THE GARAGE. **BOARD UP OF THE METAL GARAGE DOOR BY DAMIEN TOOK FOUR SHEETS OF PLYWOOD.
04/27/2016 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved FOUND WORK COMPLETED UNDER PERMIT T15CMO8968. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T15DV06953
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 8
Date Name
09/23/2015 CONTACTED IN PERSON
09/23/2015 CONTACTED BY MAILING
09/23/2015 NOTICE AND ORDER ISSUED
09/23/2015 NOTICE OF VIOLATION ISSUED
11/14/2016 VIOLATION CLOSED
12/02/2015 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
09/29/2015 STRUCTURE SECURED BY ???
09/23/2015 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
06953.PDF DOCUMENTS VIEW