Description:

NO MAIN BREAKER ON THE MAIN PANEL. ELECTRICAL ISSUES- OUTLETS AND SWITCHES SPARKING / NO SMOKE DETECTORS (PREVIOUSLY REPORTED BY ANOTHER TENANT)

Case Violations

Case Number: T15DV06749
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
Violation Date Code Statue
09/24/2015 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
09/24/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T15DV06749
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/09/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item closed
10/09/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item closed
10/09/2015 NPO - SMOKE ALARMS VALDEZ Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV06749
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/22/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THERE ARE NO SMOKE DETECTORS IN THE BEDROOM OR THE ABUTTING HALLWAY. THE INTERIOR ELECTRICAL PANEL LOCATED IN THE KITCHEN IS NOT LABELED CORRECTLY. THE HALLWAY/ DINNING AREA HAVE WALL RECEPTACLES THAT ARE LOOSE AND ONE HAS A BROKEN COVER PLATE. THE BEDROOM AND LIVING ROOM HAVE WALL SWITCH WHICH DO NOT ACTIVATE ANY ELECTRICAL DEVICES, THESE WALL SWITCHES POSSIBLY DID ACTIVATE RECEPTACLES THAT HAVE BEEN REPLACED WITHOUT THE YOLK BEING CUT..
10/09/2015 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL ELECTRICAL VIOLATIONS HAVE BEEN REPAIRED TO INCLUDE THE INSTALLATION OF TWO SMOKE DETECTORS. ELECTRICAL INNONATIONS LLC CONTRACTOR SCOPE OF WORK REPORT IN SIRE CLOSE CASE

Outstanding Case Activity Conditions

Date Name Approved
09/24/2015 2011 NATIONAL ELECTRIC CODE ARTICLE 408.4 FIELD IDENTIFICATION REQUIRED. (A) CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE POSITIONS THAT CONTAIN UNUSED OVER CURRENT DEVICES OR SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A PANEL BOARD, AND LOCATED AT EACH SWITCH OR CIRCUIT BREAKER IN A SWITCH BOARD. NO CIRCUIT SHALL BE DESCRIBED IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF OCCUPANCY. Not Approved

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV06749
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
09/18/2015 CONTACTED BY PHONE
09/24/2015 CONTACTED BY MAILING
09/24/2015 NOTICE OF VIOLATION ISSUED
10/09/2015 VIOLATION CLOSED

Documents

File Name Document Type  
1860 W PROBASCO CONTRACTOR REPORT.PDF DOCUMENTS VIEW