Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

08/31/2015

Applicant:

JL LIBERTY LLC

Description:

LEAK IN THE KITCHEN AND BATHROOM. POSSIBLY COMING FROM A PIPE IN THE CEMENT. APT A

Case Violations

Case Number: T15DV06374
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 10
Violation Date Code Statue
09/15/2015 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
09/15/2015 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
09/15/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
09/15/2015 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
09/15/2015 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
09/15/2015 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
09/15/2015 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.
09/15/2015 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
09/15/2015 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
09/15/2015 T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten feet of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade.

Outstanding Inspections

Case Number: T15DV06374
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
09/08/2015 NPO(PL)-PLUMBING SYSTEM & FX VIDAL Initial inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV06374
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/04/2015 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Met with the tenant and was shown where the water was coming from under the kitchen cabinets and in the bathroom around the tub. The water was off at the time of the inspection and was turned on to check for the water leak. Once the water was turned on you could hear the water coming out of the pipes under the ground through the bathroom fixtures. Did go outside and could see the water coming out of the stem wall by the house connection through cracks in the stem wall. The water was turned off and did meet with the tenant in unit A to check if they had another place to go to due to the water was going to be turned off. They were going to make calls to check to find a place to stay. The tenants did have other issues and did check the unit for the complaints. Did find ceramic tiles loose or missing on the tub and shower surround, globes are lacking through out, vent cover and motor are lacking in the bathroom, windows don't lock, smoke detectors are lacking in the bedrooms, open ground and reversed wiring on the outlets which may have 2-wire system on a ground outlets, bathroom door hard to close and has to be force to close, and the front door is not sealed. The owner did show to the property and did go over the issues on the unit. Did ask if he had a place to stay for the tenants and he stated no. Did go over the unit being condemned due to the water needed to be turned off at the house connection and will be requesting being capped to not allow water to the unit. While turning the water off to unit A, the water was being turned off to unit B. Will now have to check unit B. While doing the paper work for the owner, the tenants did come and stated that they found a place to stay and will need time until 7:00 PM to get items out of the unit for the night. They will come back tomorrow to remove other items out to the new location. The owner signed all the paper work. Did call supevisor Rick Saldate and was given permission on shut down due to the owner was not able to get the water to stay on. Will do N.O.V. RV.
02/17/2016 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The property is vacant and secured. The owner will be remodling at at a later time. The permit has been issued, T16CM01121 on 2-16-16 and has called blue stake to make the repairs. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T15DV06374
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
09/03/2015 CONTACTED BY PHONE
11/14/2016 VIOLATION CLOSED

Documents

File Name Document Type  
PICTURE 1374.JPG DOCUMENTS VIEW
PICTURE 1357.JPG DOCUMENTS VIEW
PICTURE 1358.JPG DOCUMENTS VIEW
PICTURE 1359.JPG DOCUMENTS VIEW
PICTURE 1360.JPG DOCUMENTS VIEW
PICTURE 1361.JPG DOCUMENTS VIEW
PICTURE 1362.JPG DOCUMENTS VIEW
PICTURE 1363.JPG DOCUMENTS VIEW
PICTURE 1364.JPG DOCUMENTS VIEW
PICTURE 1365.JPG DOCUMENTS VIEW
PICTURE 1366.JPG DOCUMENTS VIEW
PICTURE 1367.JPG DOCUMENTS VIEW
PICTURE 1368.JPG DOCUMENTS VIEW
PICTURE 1369.JPG DOCUMENTS VIEW
PICTURE 1370.JPG DOCUMENTS VIEW
PICTURE 1371.JPG DOCUMENTS VIEW
PICTURE 1372.JPG DOCUMENTS VIEW
PICTURE 1373.JPG DOCUMENTS VIEW
5001 S. LIBERTY NOV.PDF DOCUMENTS VIEW