Case: T15DV05081
Case Details
Entered Date:
07/14/2015
Applicant:
JENNIFER LYNN FERGUSON
Description:
structual damage by bulldozer / fire
Outstanding Inspections
Case Number: T15DV05081
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 7
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/04/2015 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | LOPEZ | Item closed | |
| 12/04/2015 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | LOPEZ | Item closed | |
| 12/04/2015 | NPO(PL)-PLUMBING SYSTEM & FX | LOPEZ | Item closed | |
| 12/04/2015 | NPO(PL)-GAS SUPPLY/CONNECT | LOPEZ | Item closed | |
| 12/04/2015 | NPO(DL)-DILAPIDATED STRUCTURE | LOPEZ | Item closed | |
| 12/04/2015 | NPO - EXT. BUILDING MAINTENANC | LOPEZ | Item closed | |
| 12/04/2015 | NPO - INT. BUILDING MAINTENANC | LOPEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T15DV05081
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/14/2015 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | A D-5 SIDE BOOM TRACK TRACTOR, WAS STOLEN AND SET FREE BY TYING THE DIRECTIONAL CONTROLS WITH A ROPE AND ENGAGING THE THROTTLE. THE UNMANNED TRACTOR CROSSED HOUGHTON RD AND ENTERED THE REAR OF THE PROPERTY LOCATED AT 8789 E DESERT RAINBOW DR CAUSING DAMAGE TO THE PERIMETER FENCE BLOCK WALL, THE TRACTOR CONTINUED ONTO THE ADJACENT PROPERTY ADDRESSED 8783 S DESERT RAINBOW DR THEN OVER THE PROPERTY LINE WALL, THEN KNOCKING DOWN THE ATTACHED WOOD FRAMED PATIO. AT THIS POINT THE TRACTOR ENTERED THE DWELLING BY DEMOLISHING THE EXTERIOR WALLS AND ROOF ASSEMBLY OF THE MASTER BEDROOM, ADJACENT BEDROOM AND THE MASTER BATHROOM. THIS IS WHEN THE DWELLING CAUGHT FIRE WHICH BURNED THE REMAINING ROOF MEMBERS TO INCLUDE THE ROOF SHEATHING. ESTIMATE DAMAGE IS ABOUT 70 PERCENT OF THE DWELLING'S ROOF STRUCTURE. THERE ALSO DAMAGE TO THE INTERIOR WALLS, WINDOWS, DOORS AND DRYWALL. THERE IS DAMAGE TO THE DWELLING'S ELECTRICAL DEVICES AND WIRING IN THE DEMO AREA AND CEILING AREA. THE ELECTRICAL POWER AND GAS WERE SHUT TO THE UNIT. THE UNIT WAS CONDEMNED UNFIT TO OCCUPY PLACARD POSTED. SCHEDULE A 60 DAY FOLLOW UP INSPECTION. |
| 12/04/2015 | INSP - FOLLOW UP CODE ENFORCE | LOPEZ | Approved | All permit's have been obtained will be closing this case. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T15DV05081
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 07/15/2015 | CONTACTED IN PERSON |
| 07/15/2015 | NOTICE AND ORDER ISSUED |
| 07/15/2015 | STRUCTURE SECURED BY ??? |
| 07/15/2015 | CALLBACK |