Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

06/24/2015

Applicant:

DUNG TRI VAN

Description:

HOUSE FIRE (T1542108)

Outstanding Inspections

Case Number: T15DV04609
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
06/24/2015 NPO - OTHER BARRON Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV04609
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/24/2015 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATORS, IT APPEARED THAT THE FIRE STARTED OUTSIDE, BURNED THE WASHER / DRYER UTILITY ROOM AND REAR PORCH THEN MOVED INSIDE TO THE KITCHEN DINING ROOM, AND FURTHER INTO THE LIVINGROOM. EXTERIOR WALLS AND DIVING WALL ARE ALL CMU BLOCK. FINDINGS ARE AS FOLLOWS: > POWER TURNED OFF AT THE PEDESTAL TO THE REAR OF THE BUILDING. FEEDS FROM PEDESTAL TO PANEL REMOVED. >SOUTHWEST GAS REMOVED METER DUE TO FIRE DAMAGE TO THE METER ALSO AT THE REAR OF THE PROPERTY. > REAR UTILITY ROOM AND REAR PORCH DESTROYED BY FIRE AND PORCH COLLAPSED. > KITCHEN AND DINING ROOM COMPLETELY GUTTED BY FIRE.ELECTRICAL WIRING OUTLES, AND SWITCHES INCLUDING FIXTURES DAMAGED BY FIRE. PLUMBING FIXTURES DAMAGED BY FIRE AS WELL. RAFTERS AND WLL STUDS ALSO FIRE DAMAGED. > LIVING ROOM RECEIVED SOME FIRE DAMAGE AND EXTENSIVE WATER DAMAGE. ABOUT 50 % OF THE CEILNG DRYWALL REMOVED. ELECTRICAL LEFT EXPOSED. > N/W AND S/W BEDROOMS RECEIVED SMOKE AND HEAVY WATER DAMAGE. > HALLWAY, SOME FIRE DAMAGE. HEAVY SMOKE AND WATER DAMAGE. DRYWALL SOAKED. > REAR BATHROOM RECEIVED FIRE DAMAGE, ALL ELECTRICAL AND PLUMBING FIXTURES FIRE AND SMOKE DAMAGED. ** NOV ISSUED TO OWNER DUNG TRI VAN. OWNER PLACED BY RED CROSS. OWNERS INSURANCE CONTACTED AT THE TIME OF FIRE. ** ARCAIDEN WAS CALLED TO SECURE FRONT 6-OX 4-0 WINDOW, REAR 6-0 X 6-8 SLIDING GLASS DOOR AND 4-0 X 4-0 WINDOW IN THE REAR. PORCH BEAM WAS POSTED UU TO SECURED FALLING BEAM AND ROOF RATERS. NOV ISSUED TO OWNER FOR PERMITS REQUIRED A ND EMERGENCY VACATE NOTICE.
12/07/2015 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved FOLLOW UP INSPECTION FOUND STRUCTURE WILL BE COMPLETED UNDER PERMIT T15CMO8223, PERMIT IS VALID UNTIL 6/01/2016. FOLLOW UP INSPECTION FOR F/01/2015.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T15DV04609
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
07/13/2015 CONTACTED IN PERSON
07/13/2015 NOTICE OF VIOLATION ISSUED
01/22/2016 PERMIT ISSUED - T##XX#####
06/07/2017 VIOLATION CLOSED
10/13/2015 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
07/16/2015 STRUCTURE SECURED BY ???

Documents

File Name Document Type  
04609.PDF DOCUMENTS VIEW