Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

06/10/2015

Applicant:

MEDINA JACQUELYN

Description:

HOUSE FIRE

Outstanding Inspections

Case Number: T15DV04219
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
06/11/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Follow-up inspection
06/11/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Follow-up inspection
06/11/2015 NPO(PL)-GAS SUPPLY/CONNECT VALDEZ Follow-up inspection
06/11/2015 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV04219
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/10/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: HOUSE FIRE THERE IS ONE BROKEN WINDOW 5040 XO. THIS WINDOW WAS BOARDED. THERE IS FIRE DAMAGE TO THE UTILITY ROOM'S WALLS AND ROOF MEMBERS, THE STUDS AND ROOF PLANKING HAVE DEEP CRACKS AND ARE CHARRED SEVERLY BURNT ALONG WITH THE BUILT UP ROOF SYSTEMS CONSISTING OF RAFTERS, RIDGE BOARD AND THE CEILING JOISTS. THIS ROOM IS LOCATED IN THE CENTER OF THE DWELLING. THERE IS A 4X4 ROOF CUT OUT. THE INTERIOR WALLS AND CEILINGS DRYWALL IS DAMAGE AND COVERED IN SMOKE. THERE ARE INSPECTION HOLES 2'X2' IN THE CEILINGS DRYWALL IN THE KITCHEN AND LIVING ROOMS. THE UTILITY ROOM HAS BARE AND BURNT WIRING. TEP DID REMOVE THE METER, SWG DID PINNED THE METER OFF. THERE IS SEVERE SMOKE DAMAGE TO THE ENTIRE HOME. BOTH APPLIANCES: WATER HEATER AND THE FURNACE ARE DESTROYED TO INCLUDE THE DUCT WORK. SCHEDULE A FOLLOW UP INSPECTION FOR 60 DAYS FOR AREA INSPECTOR.
06/11/2015 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved EMERGENCY CALL OUT BY TFD: REKINDLED HOUSE FIRE: THERE IS ADDITIONAL DAMAGE TO THE ATTIC AREA AND THE BUILT UP ROOF SYSTEMS CONSISTING OF THE RAFTERS AND CEILING JOISTS LOCATED ABOVE THE UTILITY ROOM, THE ABUTTING HALLWAY AND THE EASTSIDE BEDROOM. HAS ROOF DAMAGE ESTIMATED AREA OF 16 FEET BY 20 FEET. ADDITIONAL INSPECTIONS HOLES IN THE DIAMETER OF 2 FEET BY 2 FEET ARE LOCATION IN THE DINNING, KITCHEN AND LIVING AREAS. THE DRYWALL IS NOW DESTROYED IN THE EASTSIDE BEDROOM AND HALLWAY. THE EASTSIDE BEDROOM ATTIC AREA IS WHERE THE MAJORITY OF THE DWELLINGS ELECTRICAL HOME RUNS ARE LOCATED. THESE ELECTRICAL CABLE ARE NOW BARE AND MELTED. THE ABUTTING EXTERIOR WALL IS WHERE THE MAIN DISCONNECT IS LOCATED. TEP DID DISCONNECT THE SERVICE ENTRANCE CONDUCTORS FROM THE POLE. SWG DID CONDUCT AN INSPECTION OF THE METER AND THE METER REMAINS PINNED OFF. TFD STATED THAT THE FRONT DOOR WAS OPENED SO THERE WAS NO FORCE ENTRY. I DID LOCK THE REAR BEDROOM SLIDER DOOR, FRONT DOOR AND THE READ DOOR. ADDITIONAL PHOTOS AND ALL REPORT ARE IN SIRE. SCHEDULE THE AREA INSPECTOR FOLLOW INSPECTION WITHIN 60 DAYS.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T15DV04219
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
06/11/2015 CONTACTED BY PHONE
06/10/2015 CONTACTED IN PERSON
06/10/2015 NOTICE AND ORDER ISSUED
03/21/2016 VIOLATION CLOSED
10/12/2015 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
06/22/2015 STRUCTURE SECURED BY ???
06/10/2015 CALLBACK

Documents

File Name Document Type  
8.JPG DOCUMENTS VIEW
1.JPG DOCUMENTS VIEW
2.JPG DOCUMENTS VIEW
3.JPG DOCUMENTS VIEW
4.JPG DOCUMENTS VIEW
5JPG.JPG DOCUMENTS VIEW
6.JPG DOCUMENTS VIEW
7.JPG DOCUMENTS VIEW
DOCUMENTS AND IMAGES T15DV04219.PDF DOCUMENTS VIEW