Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL

Entered Date:

05/26/2015

Applicant:

LUIS & ANNA M MIRELES CP/RS

Description:

work without permit- plumbing and removal of facia, walls etc...

Outstanding Inspections

Case Number: T15DV03937
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
07/09/2015 NPO - WORK WITHOUT PERMIT VALDEZ Extension granted

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV03937
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/09/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ONSITE INSPECTION RESULTS: A STOP WORK ORDER WAS ISSUED: THE OWNER / CONTRACTOR IS WORKING OUTSIDE OF THE SCOPE OF HIS PERMIT T15CM03289 WHICH IS A RECONNECT ELECTRIC; RES R1: ADD CARPORT (T15DV03937). INSPECTION RESULTS AS FOLLOWS: EXTERIOR ENCLOSURE HAS A WATER HEATER IS MISSING. THE INTERIOR BEARING WALLS HAVE BEEN REMOVED FROM THE KITCHEN / LIVING ROOM. THERE IS A BEAM WHICH IN THIS AREA NOW SHOWS SIGNS OF DEFLECTION DUE TO THE SPAN. THERE IS A NEW ELECTRICAL PANEL WITH NEW CIRCUIT BREAKERS WHICH HAS BEEN INSTALLED IN THE BEDROOMS CLOSET. THERE ARE NEW OUTLETS WITH RECEPTACLES AND SWITCHES IN THE ENTIRE DWELLING. THERE IS NEW NON-METALLIC SHEATHED ELECTRICAL CABLE NUMBER 12 AND 10 THAT ARE RUNNING PARALLEL WITH THE RAFTERS AND IN THE WALL CAVITIES. SOME OF THE RAFTERS HAVE BEEN BORED FOR THESE ELECTRICAL CABLES. BOTH BATHROOMS HAVE A SLAB CUT FOR A NEW TUB DRAIN INSTALL, THERE IS A NEW SHOWER VALVE THAT WAS INSTALLED IN ONE BATHROOM. THE TUBS HAVE BEEN REMOVED IN BOTH BATHROOMS. ONE OF THE BATHROOMS HAS NEW WALL BOARD INSTALLED. THE ABUTTING BEDROOM HAS COILS OF PEX TUBING.
07/09/2015 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved 07/09/2015 PERMIT ISSUED T15CM04218. J VALDEZ CASE T15DV03937-REMODEL OF SFR EXPIRES 01/05/2016..

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T15DV03937
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
06/10/2015 CONTACTED BY PHONE
06/10/2015 CONTACTED BY MAILING
06/10/2015 STOP WORK ORDER ISSUED
06/10/2015 NOTICE OF VIOLATION ISSUED
02/03/2016 VIOLATION CLOSED

Documents

File Name Document Type  
NOV T15DV03937.PDF DOCUMENTS VIEW
FULLSIZERENDER_8.JPG DOCUMENTS VIEW
FULLSIZERENDER.JPG DOCUMENTS VIEW
FULLSIZERENDER_1.JPG DOCUMENTS VIEW
FULLSIZERENDER_2.JPG DOCUMENTS VIEW
FULLSIZERENDER_3.JPG DOCUMENTS VIEW
FULLSIZERENDER_4.JPG DOCUMENTS VIEW
FULLSIZERENDER_5.JPG DOCUMENTS VIEW
FULLSIZERENDER_6.JPG DOCUMENTS VIEW
FULLSIZERENDER_7.JPG DOCUMENTS VIEW
9.JPG DOCUMENTS VIEW