Case: T15DV03475
Case Details
Entered Date:
05/11/2015
Applicant:
DUALEH KHADRA A
Description:
EMERGENCY / HOUSE FIRE
Outstanding Inspections
Case Number: T15DV03475
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/02/2015 | NPO - WORK WITHOUT PERMIT | GOODMAN | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T15DV03475
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/09/2015 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, MET WITH TFD WHO STATED FIRE HAD STARTED IN THE KITCHEN AREA AND ALTHOUGH CONTAINED TO THE KITCHEN THERE WAS VERY HEAVY SMOKE DAMAGE THRU OUT. >CHECKED ELECTRICAL WHILE WAITING TO BE ALOWED ENTRY, SERVICE PANEL WAS WELL MARKED, PANEL FED A INTERIOR SUB PANEL. POWER WAS TURNED OFF AT THE MAIN DISCONNECT AND LATER FOUND A MAJORITY OF THE BREAKERS IN THE OFF POSITION. > S/W GAS WAS ON SITE, FOUND NO PROBLEMS WITH THE EXTERIOR GAS LINES AFTR DOING A LINE CHECK, BUT AFTER CONVERSING WITH TFD DETERMINED TO LEAVE THE GAS OFF AND PIN THE METER DUE TO A FAULTY VALVE ON THE GAS COOK TOP. >ENTERED THE KITCHEN AREA FOUND CEIING REMOVED AND SEVERAL AREAS IN THE WALL REMOVED. BUILDING WAS PLASTER, LATHE (BOARD) AND PLASTER HAD BEEN REMOVED FROM THE CEILING AND EAST KITCHEN WALL EXPOSING ELECTRICAL WIRING IN BOTH AREAS. >SOUTH, EAST AND NORTH WALLS RECIEVED FIRE DAMAGE, STUDS APPEAR TO BE OK, NO FIRE DAMAGE. >ELECTRICAL IN THE CEILING WAS FIRE DAMAGED, WIRING AND FIXTURES FIRE DAMAGED. SWITCHES AND OUTLETS IN THE WALLS FIRE DAMAGED. WIRING IN BOTH THE CEILING AND WALLS LEFT EXPOSED. >ENTERING THE HOUSE, FOUND LIVINGROOM, DINING ROOM DIRECTLY TO THE EAST, HALL TO THE NORTH AND FAMILY ROOM IN THE BACK ALL RECEIVED VERY HEAVY FIRE DAMAGED. HOLES WERE PLACED IN ALL AREAS BY TFD CHECKING FOR FIRE SPREAD. LIGHT FIXTURES WERE FOUND FIRE DAMAGED. > ROOF SECTION IN THE LIVINGROOM ALSO FOUND CUT BY TFD ATTIC SPACE WAS FREE OF FIRE DAMAGE. >HALL TO EAST BEDROOMS, BEDROOMS AND HALL BATH ALL RECEIVED MINOR SMOKE DAMAGE. N/E BEDROOM ALSO HAD SMOKE DAMAGE. > ALL KITCHEN CABINETS AND FIXTURES WERE FOUND FIRE DAMAGED.>PLUMBING IN WALLS POSSIBLE HEAT DAMAGE. >PLUMBING IN THE KITCHEN MAY HAVE RECEIVED HEAT DAMAGE TO THE HEAVY FIRE IN THE AREA. >FOUND SOOT IN ALL DUCTWORK AND GRILLES. EMERGENCY NOV TO EVACUATE ISSUED. BUILDING NOV ISSUED FOR DAMAGE AND INDEMNIFICATION ISSUED DUE TO OWNERS TAKING RESPONSIBILITY TO LOCK UP AFTER I HAD LEFT. |
| 12/02/2015 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | WORK COMPLETED UNDER PERMIT T15CM04419 AND FINALED ON 8/07/2015. COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - RESIDENTIAL FIRE
Case Number - T15DV03475
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
| Date | Name |
| 11/14/2016 | VIOLATION CLOSED |