Case Number: T15DV01336
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
11/05/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Item closed
11/05/2015 NPO(PL)-PLUMBING SYSTEM & FX GOODMAN Item closed
11/05/2015 NPO(PL)-GAS SUPPLY/CONNECT GOODMAN Item closed
11/05/2015 NPO - WORK WITHOUT PERMIT GOODMAN Item closed
11/05/2015 NPO - INT. BUILDING MAINTENANC GOODMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T15DV01336
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/26/2015 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MYSELF AND INSPECTOR SONYA MUNOZ, MET WITH TFD FIRE INVESTIGATORS WHO HAD NOT YET BEEN INSIDE THE BUILDING. CHECKED ELECTRICAL METER, POWER HAD BEEN SHUT OFF BY TFD AND METER PINNED BY TEP. SPOKE WITH S/W GAS WHO STATED THERE WAS NO GAS TO THE PROPERTY. SPOKE TO PRPERTY MANAGER CINDY KLINE WHO STATED OWNERS WERE OUT OF TOWN IN MEXICO THAT THEY HAVE A SUMMER HOME IN MEXICO WHERE THEY SPEND ALOT OF TIME AND NOT SURE HOW LONG THEY HAD BEEN GONE. LOCATED BROTHER OF THE OWNER FELLIPE CHAVEZ WHO STATED HE WAS ON HIS WAY, BROTHER IS PRESENTLY IN HERMOSILLO . INSPECTION FINDINGS ARE AS FOLLOW: ENTERING THE FRONT DOOR INTO THE LIVINGROOM AREA, FOUND HEAVY SMOKE DAMAGE, BLINDS MELTED MINOR DRYWALL DAMAGED FROM TFD. > KITCHEN AND DINING AREA ALSO RECEIVED VERY HEAVY SMOKE DAMAGE, ALL PLUMBING AND LIGHT FIXTURES BAD ENOUGH THAT THEY MAY NEED TO BE REPLACED. DRYWALL PROBABLY REQUIRES REPLACEMENT. >HALL AND HALL BATHROOM DID RECEIVE HEAY FIRE DAMAGE. DROPPED CEILING IN THE HALL HAD BEEN REMOVED. DRYWALL DAMAGE IN THE BATHROOM AND HALL. PLUMBING AND ELECTRICAL FIXTURES RECEIVED VERY HEAVY HEAT AND SMOKE DAMAGE. POSSIBLLE HEAT DAMAGE TO PLUMBING LINES. HALL CLOSETS GUTTED BY FIRE. HVAC DUCTWORK FIRE DAMAGED. FIRE DAMAGE TO ELECTRICAL SYSTEM. > EAST BDRM OFF THE HALL RECEIVED MINOR FIRE DAMAGE, HEAVY SMOKE AND WATER DAMAGE. DRYWALL REMOVED OFF THE CEILING. POSSIBLE HEAT DAMAGE TO ELECTRICAL SYSTEM. > REAR OR NORTH MASTR BDRM/BATHROOM GUTTED BY FIRE. ELECTRICAL, PLUMBING, HVAC ALL FIRE DAMAGED. FRAMING AND DRYWALL FIRE DAMAGED. ROOF SYTEM FIRE DAMAGED, TRUSSES BURNED AND SOME CUT BY TFD. >STRUCTURE WAS SECURED BY BATHCREST, (1) 6-0 X 5-0 WINDOW, 1 3-0X 4-0 WINDOW AND (1) 8-0 X 6-8 SLIDING GLASS DOOR. >EMERGENCY VACATE NOV ISSUED AND SIGNED FOR BY BROTHER FELLIPE CHAVEZ DUE TO OWNERS BEING IN MEXICO.
09/09/2015 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved ALL WORK COMPLETED UNDER PERMIT T15CMO2078 AND ALL INSPECTIONS APPROVED AND PERMIT FINALED. COMPLIANCE / CLOSE CASE.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T15DV01336
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
04/20/2015 CONTACTED BY PHONE
04/20/2015 NOTICE OF VIOLATION ISSUED
11/05/2015 VIOLATION CLOSED
07/25/2015 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
03/19/2015 STRUCTURE SECURED BY ???