Case: T14DV10387
Case Details
Entered Date:
12/31/2014
Applicant:
SEABURY INC
Description:
UNIT #4 ---> SWGAS DETECTED A LEAK AND SHUT GAS OFF -
Case Violations
Case Number: T14DV10387
Case Status: COURTCMP
Case Description: RES: MINIMUM HOUSING
Total Violations: 4
| Violation Date | Code Statue |
|---|---|
| 01/23/2015 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 01/23/2015 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition. |
| 01/23/2015 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
| 01/23/2015 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
Outstanding Inspections
Case Number: T14DV10387
Case Status: COURTCMP
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2015 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | HOLLANDER | Item closed | |
| 10/06/2015 | NPO(PL)-PLUMBING SYSTEM & FX | HOLLANDER | Item closed | |
| 10/06/2015 | NPO(HC)-HEATING & VENTILATION | HOLLANDER | Item closed | |
| 10/06/2015 | NPO - WORK WITHOUT PERMIT | HOLLANDER | Item closed | |
| 12/31/2014 | NPO(PL)-GAS SUPPLY/CONNECT | BENCOMO | Item initialized |
Completed Inspections
Case Status: COURTCMP
Case Number: T14DV10387
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/05/2015 | INSP - INITIAL CODE ENFORCMENT | HOLLANDER | Approved | Meet owner on site. There are numerous electrical violations. The gas has been disconnected by Southwest gas. The owner is to reduce the fuse size to 20A to allow the use of a space heater on a temporary basis. He is also to reduce the size of the space heater that is in use. Took photos. |
| 10/06/2015 | INSP - FOLLOW UP CODE ENFORCE | HOLLANDER | Approved | Took pictures for court. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV10387
Case Status: COURTCMP
Total Completed Case Activity Conditions: 7
| Date | Name |
| 03/09/2015 | CONTACTED BY PHONE |
| 01/26/2015 | CONTACTED BY MAILING |
| 08/07/2015 | CERTIFIED RECEIPT CARD |
| 01/26/2015 | NOTICE OF VIOLATION ISSUED |
| 04/28/2015 | LONG FORM CITATION |
| 10/08/2015 | VIOLATION CLOSED |
| 07/28/2015 | COURT HEARING INFO |