Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

12/29/2014

Applicant:

GERACI DIANA MAREE

Description:

NO HEAT - HAS PORTABLE HEATERS

Case Violations

Case Number: T14DV10323
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
Violation Date Code Statue
01/06/2015 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
01/06/2015 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T14DV10323
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
03/12/2015 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item closed
03/12/2015 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item closed
12/29/2014 NPO(HC)-HEATING & VENTILATION BENCOMO Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV10323
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/06/2015 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ON SITE INSPECTION; THE HEAT PUMP IS NOT BLOW HOT AIR, THE UNIT IS MOUNTED ON ROOF AND IS MAKING A NOISE. THE EQUIPMENT DISCONNECT IS MISSING THE COVER.. THE MAIN DISCONNECT IS A CUTLER HAMMER AND HAS UNLABELED CIRCUIT BREAKERS. THERE IS ALSO MIS MATCH BREAKER. THE FRONT OF THE HOME HAS A BLANK COVER ON THE OUTDOOR RECEPTACLE. THE REAR OUTDOOR IS LOOSE AND NOT PROPERLY SECURED.
03/12/2015 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved HEAT PUMP IS WORKING FINE ACCORDING TO THE CONTRACTOR AND THE TENANT.. CLOSE CASE

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV10323
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/05/2015 CONTACTED BY PHONE
01/16/2015 CONTACTED BY MAILING
01/16/2015 NOTICE OF VIOLATION ISSUED
03/12/2015 VIOLATION CLOSED