Case Details

Status:

Closed - Resolved

Type:

EMERGENCY / FIRE

Entered Date:

11/01/2014

Applicant:

N/A

Description:

Completed Inspections

Case Status: Closed - Resolved
Case Number: T14DV09201
Case Description: EMERGENCY / FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/04/2014 COT - ENFC - Code Enforcement - Initial Passed {Activity date: 11/04/2014; Status: Approved; Inspector: GOODMAN; Comment: Entered by GOODMAN - VISITED SITE, MET WITH TFD FIRE CHIEF ROB RODRIQUEZ WHO INTRODUCED ME TO TENANTS THOMAS WISBEY AND GENGIZ NACE ARK, WHO IN TURN GAVE THE OWNER AS DAN JAMES. MAINTANENCE PERSON YISHI GARRARD WAS CONTACTED AND WOULD CALL MR JAMES. FIRE STARTED IN THE S/W BEDROOM AND MOVED THRU THE APT. ALL EXTERIOR WALLS AND PARTING WALLS BETWEEN UNITS WERE CYNDER BLOCK WALLS, PARTING WALLS WENT TO THE ROOF LINE. SERVICE PANEL FOR EACH UNIT WAS ON THE NORTH SIDE OF THE 3-PLEX AND WIRING FED THE UNITS FROM NORTH TO SOUTH. >TFD TURNED POWER OFF TO THE 3-PLEX UPON ARRIVAL > S/W GAS RAN A LINE TEST AND TEST CHECKED OUT OK. WHEN CHECKING APPLIANCES AND GAS HEAT PACKS MINOR LEAKS WERE FOUND. >INTERIOR OF BLOCK WALLS WERE PLASTERED, INTERIOR FRAMED WALLS ALSO PLASTERED AS WELL AS THE CEILINGS. OPENED CEILING AND WALLS FOUND NO FIRE DAMAGE TO THE FRAME WALLS OR RAFTERED ROOF SYSTEM. VENT HOLES WERE CUT IN THE 1X10 ROOF DECKING. >LIVING ROOM WAS FIRE DAMAGED, 1/2 OF CEILING WAS REMOVED. PLASTER ON THE FRAMED WALLS ALSO FIRE DAMAGED. >KITCHEN / DINING AREA ALSO FIRE AND HEAVY SMOKE DAMAGE TO THE WALLS AND CEILING. >HALLWAY RECEIVED HEAVY FIRE DAMAGE, DOOR TO HALL CLOSET BURNED THRU, CONTENTS IN HALL CLOSET AND THE SUB PANEL ALL FIRE DAMAGED. WIRING TO SUB PANEL COMPLETELY BURNED. FRAMING FIRE DAMAGED. >S/E BEDROM AND BATHROOM ALSO RECEIVED FIRE DAMAGE AND VERY HEAVY SMOKE DAMAGE TO PLASTER AND PLASTER LATH. >ELECTRICAL TURNED OFF AT THE MAIN SERVICE PANEL AND PANEL LOCKED OUT BY TEP. ELECTRICAL THAT FEEDS SUBPANELS FOR UNIT 1427 & 1425 ALSO RUNS THRU THE ATTIC AREA OF UNIT 1429 >ROOF DAMAGE FROM VENT HOLES CUT IN THE ROOF. ** NOV'S ISSUED TO MANAGER YISHI GARRARD. UNIT 1429 VACATED AND POSTED "UNFIT TO OCCUPY" ALL WINDOWS AND DOORS TO BE SECURED BY MR GARRARD. INDEMNIFICATION ISSUED FOR THE SECURING. FRONT AND REAR DOOR OPENING SECURED BY THE WROUGHT IRON DOOR.}
11/14/2022 COT - ENFC - Code Enforcement - Follow Up Passed

Scheduled Inspections

SCase Number - T14DV09201
Case Status: Closed - Resolved
Case Description:
Scheduled Date Description Inspector Status
COT - ENFC - Code Enforcement - Initial Scheduled

Completed Case Activity

Case Number - T14DV09201
Case Status: Closed - Resolved
Case Description: EMERGENCY / FIRE
Description Date Status
PERMIT ISSUED - T##XX##### 09/25/2015 Passed
NOTICE OF VIOLATION ISSUED 11/01/2014 Passed
CONTACTED IN PERSON 11/01/2014 Passed
CALLBACK 11/01/2014 Passed

Documents

File Name Document Type  
T14DV09201.PDF DOCUMENTS VIEW