Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

11/03/2014

Applicant:

DEED & NOTE TRADERS LLC

Description:

EMERGENCY/ HOUSE FIRE

Outstanding Inspections

Case Number: T14DV09178
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
10/30/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX GOODMAN Notice of violation
10/30/2014 NPO(PL)-WATER HEATERS GOODMAN Notice of violation
10/30/2014 NPO(DL)-DILAPIDATED STRUCTURE GOODMAN Notice of violation
10/30/2014 NPO - WORK WITHOUT PERMIT GOODMAN Notice of violation

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV09178
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/03/2014 INSP - INITIAL CODE ENFORCMENT GOODMAN Approved VISITED SITE, MET WITH TFD INVESTIGATORS WHO STATED THE FIRE HAD STARTED IN THE HOTWATER HEATER ROOM WHICH IS ENTERED FROM THE CARPORT AREA, AND THEN ENTERED INTO THE ATTIC SPACE OF THE TRUSSED ROOF. FIRE DID RUN THRU THE ATTIC AREA . SEVERAL TRUSSES ABOVE THE HOTWATER HEATER ROOM WERE BURNED COMPLETELY THRU AND TRUSSES ALL THE WAY TO THE FRONT OF THE STRUCTURE RECEIVED MINOR FIRE DAMAGE/ HEAVY SMOKE DAMAGE AS WELL AS THE ROOF SHEATHING. THE FRONT PORCH CEILING DRYWALL HAD BEEN REMOVED AND THE TRUSSES AND SHEATHING WERE VIEWABLE. LARGE VENT HOLES WERE CUT IN THE ROOF SHEATHING. >FRAMING TO THE HOTWATER HEATER ROOM AND INTERIOR CLOSET WERE FIRE DAMAGED. >ENTERER THE INTERIOR OF THE STRUCTURE, FOUND MOSTLY WATER DAMAGE TO THE CEILING DRYWALL AND VENT HOLES WERE CUT IN EVERY CEILING OF EVERY ROOM. SMOKE DAMAGE THRU OUT. >ELECTRICAL SET UP FOR THE FURNACE AND HOTWATER HEATER ROOM WAS FIRE DAMAGED, EXPOSED BURNED WIRING HANGING FROM THE CEILING. MAIN SERVICE PANEL ALSO SHOWED NUETRAL BAR DBL AND TRIPLE LUGGED, PANEL SHUT OFF BY TFD AND PINNED BY TEP. > NO GAS TO THE STRUCTURE PER S/W GAS. ALL WINDOWS AND DOORS WERE LOCKABLE, ONLY FRONT DOOR WAS LEFT OPEN SO THAT OCCUPANTS COULD REMOVE PERSONAL BELONGINGS.
09/25/2015 INSP - FOLLOW UP CODE ENFORCE GOODMAN Approved ALL FIRE DAMAGED WORK COMPLETED UNDER PERMIT T15CMO0838 AND FINALED 8/14/2015

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T14DV09178
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
11/04/2014 CONTACTED IN PERSON
11/04/2014 NOTICE OF VIOLATION ISSUED
10/06/2016 VIOLATION CLOSED