Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

10/23/2014

Applicant:

JOHN & BARBARA A RYAN JT/RS ATTN: RINCON REALTY & INVESTMENTS

Description:

EXPOSED WIRES IN LIVING ROOM ADDITIONAL ELECTRICAL ISSUES.

Case Violations

Case Number: T14DV08916
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 3
Violation Date Code Statue
11/14/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
11/14/2014 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
11/14/2014 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T14DV08916
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
12/18/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX VINDIOLA Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV08916
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/12/2014 INSP - INITIAL CODE ENFORCMENT VINDIOLA Approved ** EXPOSED WIRES IN LIVING ROOM ADDITIONAL ELECTRICAL ISSUES ** 11/07/14 - ARRIVED ON SITE MET WITH TENANTS AND SHOWED ME THRU TWO BEDROOM HOME // LIVING ROOM AREA WITH OUTLETS WITH OPEN GROUNDS AND LOOSE OUTLETS // ARIZONA ROOM WITH 3 OUTLETS LOOSE // KITCHEN WITH OPEN GROUND ALONG COUNTER OUTLET & CEILING WITH PAINT PEELING // HALLWAY LIGHT SWITCH/LIGHT FIXTURE NOT WORKING - OPEN GROUND HALLWAY OUTLET // BATHROOMS WITH OPEN GROUNDS ON OUTLETS BY LIGHTS // OUTLETS IN BOTH BATHROOMS NEED TO BE GFCI OUTLETS // OFFICE ROOM WITH LOOSE OUTLETS AND ZIP CORD TO LIGHT BEING USED AS PERMANENT WIRING (WAS PUT BEHIND SHEETROCK WALL ) // MASTER BEDROOM ALSO HAS ZIP CORD TO LIGHT BEING USED AS PERMANENT WIRING (WAS PUT BEHIND SHEETROCK WALL ) DOOR IN MASTER BEDROOM LACKS WEATHER STRIPPING // 2 EXTERIOR OUTLETS ONE UNDER EAVES AND ABOVE 8FT HIGH NON ISSUE SECOND LACKS OUTDOOR WEATHER PROTECTED COVER // NOV TO FOLLOW // AV
12/18/2014 INSP - FOLLOW UP CODE ENFORCE VINDIOLA Approved REC'D A CALL FROM MANANGER // TENANTS MOVED OUT 2 WEEKS AGO // THEY FINISHED ALL VIOLATIONS LISTED ON NOV// PROPERTY ALL LOCKED UP // WILL MOVE TO CLOSE OUT THIS CASE// AV

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV08916
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
11/14/2014 CONTACTED BY PHONE
11/17/2014 CONTACTED BY MAILING
11/14/2014 NOTICE OF VIOLATION ISSUED
02/18/2015 VIOLATION CLOSED
12/02/2014 RESEARCH

Documents

File Name Document Type  
T14DV08916.PDF DOCUMENTS VIEW