Case: T14DV08324
Case Details
Entered Date:
10/06/2014
Applicant:
RHODES STEVEN L & PRAINITO WILLIAM R
Description:
HOUSE FIRE
Outstanding Inspections
Case Number: T14DV08324
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/08/2014 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | GOODMAN | Notice of violation | |
| 10/08/2014 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | GOODMAN | Notice of violation | |
| 10/08/2014 | NPO(PL)-PLUMBING SYSTEM & FX | GOODMAN | Notice of violation | |
| 10/08/2014 | NPO(DL)-DILAPIDATED STRUCTURE | GOODMAN | Notice of violation | |
| 10/08/2014 | NPO - WORK WITHOUT PERMIT | GOODMAN | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV08324
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/06/2014 | INSP - INITIAL CODE ENFORCMENT | GOODMAN | Approved | VISITED SITE, MET WITH TFD CAPTAIN WHO STATED THAT AT THE TIME OF THEIR ARRIVAL FLAMES WERE COMING FROM THE N/E CORNER OF THE STRUCTURE AND SHOOTING OUT OF THE ROOF VENT AT THE LIVINGROOM AREA. TFD HAD SHUT POWER OFF AT THE MAIN DISCONNECT AS WELL AS TURNING EACH BREAKER OFF. TFD CONTACTED TEP AND TEP LOCKED OUT THE METER. TFD ALSO SHUT THE GAS OFF ATTHE METER AND CONTACTED S/W GAS, S/W GAS CONDUCTED A LINE TEST BUT FOUND NO LEAKS. THE METER WAS PINNED BY S/W GAS. MY INSPECTION FOUND THE KITCHEN AT THE N/E CORNER OF THE STRUCTURE GUTTED BY FIRE, CEILING JOSITS, ROOF RAFTERS AND ROOF SHEATHING COMPLETELY GONE. STUDS TO ADJOINING ROOMS WERE EXPOSED AND CHARRED. THE FLOOR JOISTS WERE ALSO FIRE DAMAGED AND THE WOOD FLOORING BURNED ALLTHE WAY THRU TO THE CRAWL SPACE BELOW THE STRUCTURE. (POSSIBLE FIRE DAMAGE TO THE PLUMBING IN THE CRAWL SPACE. DINING AREA OFF THE KITCHEN ALSO WAS COMPLETELY FIRE DAMAGED, WITH THE ROOF SYSTEM GONE, ELECTRICAL OUTLETS, WIRING, AND FIXTURES FIRE DAMAGED AND MC CABLE LEFT EXPOSED. THE DUCT WORK IN THAT AREA ALSO FIRE DAMAGED AND LEFT EXPOSED. OFF THE DININGING AREA I ENTERED THE LIVINGROOM, THE DRYWALL WAS PULLED DOWN FROM 40% OF THE CEILING EXPOSING THE CEILING JOISTS, RAFTERS AND SHEATHING WHICH AGAIN RECEIVED HEAVY FIRE DAMAGE. THE ELECTRICAL WIRING AND DUCTWORK ALSO FIRE DAMAGED. THE ROOM NORTH OF THE LIVINGROOM, MAYBE A SITTING ROOM RECEIVED HEAVY FIRE DAMAGE TO THE WOOD CEILING AND CABINETS, AND NORTH OF THE SITTING ROOM WAS A ENCLOSED PORCH WHICH RECEIVED HEAVY FIRE DAMAGE TO THE WASHER/ DRYER CLOSET AT THE S/E CORNER OF THE ROOM AND THE REST OF THE ROOM RECEIVED VERY HEAVY SMOKE DAMAGE. THE 2 BDRMS AND BATHROOM, HALL AND FURNACE ROOM AT THE WEST END OF THE STRUCTURE RECEIVED HEAVY SMOKE DAMAGE AND THE ATTIC AREA PROBABLY RECEIVED SOME FIRE DAMAGE DUE TO THE WEST PART OF THE LIVINGROOM ATTIC SPACE STILL HEAVILY DAMAGED AND THE HALLWAY AREA STARTING WHERE THE LIVINGROOM LEFT OFF. BATHCREST PINNED THE FRONT DOOR, AND BOARDED THE KITCHEN FOOR AND KITCHEN WINDOW. *** STRUCTURE WAS VACANT AT THE TIME OF FIRE, APPEARED IT WAS BEING PAINTED, POSSIBLY REMODELED. MONDAY 10/6 TRIED CONTACTING THE OWNER ON RECORD, FOUND BY THAT PERSON THAT THE HOUSE CLOSED THE PREVIOUS WEEK. BILL PRAINITO PROVIDED REALTORS NAME AND CONTACT NUMBER. (CALVIN CASE 406-0000), (ESCROW KRISTINA MUSGRAVE/TITLE SECURITY 618-7422) |
| 10/01/2015 | INSP - FOLLOW UP CODE ENFORCE | GOODMAN | Approved | ALLWORK COMPLETED UNDER PERMIT, COMPLIANCE / CLOSE CASE. |
Completed Activity Special Conditions
Case Description - RESIDENTIAL FIRE
Case Number - T14DV08324
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 10/13/2014 | CONTACTED IN PERSON |
| 10/13/2014 | NOTICE OF VIOLATION ISSUED |
| 09/25/2015 | PERMIT ISSUED - T##XX##### |
| 10/06/2016 | VIOLATION CLOSED |
| 02/11/2015 | SEC LETTER OF BILLING FOR $??? SENT TO OWNERS |
| 11/13/2014 | STRUCTURE SECURED BY ??? |