Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

10/01/2014

Applicant:

KELLER WILLIAMS - ATTN: BEN LAIR

Description:

Electric not working - kitchen some outlets working and some do not. Bathroom outlet- Swamp cooler not working.

Case Violations

Case Number: T14DV08239
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 2
Violation Date Code Statue
10/03/2014 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
10/03/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.

Outstanding Inspections

Case Number: T14DV08239
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
10/10/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT BIGMAN Item closed
10/10/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX BIGMAN Item closed
10/10/2014 NPO(HC)-COOLING BIGMAN Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV08239
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
10/01/2014 INSP - INITIAL CODE ENFORCMENT BIGMAN Approved MET W/OCCUPANT: NO ELECTRICITY. CK INTERNAL CIR TO SEE IF ANY CIR WERE TRIPPED. NO CIR TRIPPED INSIDE. CK OUTSIDE AT METER. FOUND CIRCUIT TRIPPED. FLIPPED CIR BACK ON. WENT INSIDE AND ALL ELECTRICAL WORKING. HOWEVER THE ELECTRICAL SLOWLY DIED OUT WHILE INSIDE. CONTACTED KELLER WILLIAMS PROPERTY MGR. PROPERTY MGMT HAD MAINT FOR STONE HSE GROUP COME OUT TO CK ELECTRICAL. CONTACTED CITY ELECTRICAL INSPECTOR. DISCUSSED ISSUE. ADVISED PROPERTY MGMT THAT A ELECTRICAL PERMIT WILL BE REQUIRED AND TEP WILL BE REQUIRED AS WELL. MGMT RELOCATED OCCUPANT TO ANOTHER APT WHILE REPAIRS ARE BEING MADE UNDER PERMIT. WILL FU ON 10/3.
10/10/2014 INSP - FOLLOW UP CODE ENFORCE BIGMAN Approved BERT ELECTRIC, TEP MET ON SITE. THE EXTERIOR CIRCUIT TO THE UNIT WAS BURNED. BERTS ELECTRIC REMOVED THE CIRCUIT AND REPLACED THE BUSSBAR. ELECTRICAL SERVICE RESTORED BACK TO THE UNIT. CLOSE OUT CASE. PERMIT #T14CM06747 APPROVED.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV08239
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
10/06/2014 CONTACTED BY MAILING
10/06/2014 NOTICE OF VIOLATION ISSUED
10/17/2014 VIOLATION CLOSED