Case: T14DV06372
Case Details
Entered Date:
08/21/2014
Applicant:
GISTARO NICHOLAS M LIVING TRUST
Description:
ELECTRICAL FOR THE CEILING FAN IS NOT PUT IN CORRECTLY
Case Violations
Case Number: T14DV06372
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 09/11/2014 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 09/11/2014 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 09/11/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 09/11/2014 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
| 09/11/2014 | T.C. Ch. 16, Sec. 16-12(d) COOLERS. Evaporative coolers, cooler stands, and any cooler mounting apparatus must be maintained in a safe condition. Cooler stands and any mounting apparatus must be structurally sound. |
| 09/11/2014 | T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced. |
Outstanding Inspections
Case Number: T14DV06372
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/06/2014 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | NAVARRO | Item closed | |
| 11/06/2014 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | NAVARRO | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV06372
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/11/2014 | INSP - INITIAL CODE ENFORCMENT | NAVARRO | Approved | visited site, met tenant, inspected,there are multiple electrical issues,outside porch light,extension cord supplying the fan in living room,open and exposed wiring on exhaust fan,bathroom heater installation has open and exposed wiring,unsafe junction box-no ground,water installed no drain line,all windows are screwed closed perminatly, will write notice of violatiom |
| 11/06/2014 | INSP - FOLLOW UP CODE ENFORCE | NAVARRO | Approved | Visited site, inspected, unit is vacated, this case will be closed abated. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV06372
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 09/12/2014 | CONTACTED BY MAILING |
| 09/12/2014 | NOTICE OF VIOLATION ISSUED |
| 11/13/2014 | VIOLATION CLOSED |