Case Details

Status:

CANCEL

Type:

RES: MINIMUM HOUSING

Entered Date:

07/17/2014

Applicant:

TALAZERA HOLDING GROUP LLC

Description:

DILAPITATED ROOF (CAVING IN)

Case Violations

Case Number: T14DV04979
Case Status: CANCEL
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date Code Statue
07/23/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/23/2014 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/23/2014 T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration.
07/23/2014 T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition.
07/23/2014 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
07/23/2014 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T14DV04979
Case Status: CANCEL
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
10/30/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX MENDOZA Item closed
10/30/2014 NPO(PL)-PLUMBING SYSTEM & FX MENDOZA Item closed
10/30/2014 NPO(DL)-DILAPIDATED STRUCTURE MENDOZA Item closed
10/30/2014 NPO - EXT. BUILDING MAINTENANC MENDOZA Item closed
10/30/2014 NPO - INT. BUILDING MAINTENANC MENDOZA Item closed

Completed Inspections

Case Status: CANCEL
Case Number: T14DV04979
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/21/2014 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved Insulation from the flooring has fallen to the ground. Exterior sheathing has various holes and split in areas. Wood plate from the kitchen to the hallway is a trip hazard. Flooring throughout the unit is loose and deteriorated. North bedroom door is broken. North bedroom bathroom sink faucet is broken and leaks. Cabinet base is deteriorated. Kitchen light is missing a globe. Main bathroom light is missing a globe. Ceiling in the kitchen is deteriorated, split and sagging. Rear door does not shut properly and is not properly sealed.
10/30/2014 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved Have made several attempts to make contact with the tenant to no avail. Will close the case.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV04979
Case Status: CANCEL
Total Completed Case Activity Conditions: 4
Date Name
07/18/2014 CONTACTED BY PHONE
07/24/2014 CONTACTED BY MAILING
07/24/2014 NOTICE OF VIOLATION ISSUED
10/30/2014 VIOLATION CLOSED

Documents

File Name Document Type  
110EPRINCE#15NOV1.PDF DOCUMENTS VIEW