Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

NOVERIFY

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/11/2014

Applicant:

BERJ & CELIA FUSTUKJIAN TR

Description:

No a/c, no lights-electrical, ant infestation

Case Violations

Case Number: T14DV04708
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
Violation Date Code Statue
07/22/2014 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
07/22/2014 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
07/22/2014 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/22/2014 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/22/2014 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
07/22/2014 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.

Outstanding Inspections

Case Number: T14DV04708
Case Status: NOVERIFY
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 9
End Date Description Inspector Results Comments
10/28/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX MENDOZA Item closed
10/28/2014 NPO(PL)-PLUMBING SYSTEM & FX MENDOZA Item closed
10/28/2014 NPO(PL)-WATER HEATERS MENDOZA Item closed
10/28/2014 NPO(HC)-COOLING MENDOZA Item closed
10/28/2014 NPO(HC)-HEATING & VENTILATION MENDOZA Item closed
10/28/2014 NPO(DL)-DILAPIDATED STRUCTURE MENDOZA Item closed
10/28/2014 NPO - SMOKE ALARMS MENDOZA Item closed
10/28/2014 NPO - EXT. BUILDING MAINTENANC MENDOZA Item closed
10/28/2014 NPO - INT. BUILDING MAINTENANC MENDOZA Item closed

Completed Inspections

Case Status: NOVERIFY
Case Number: T14DV04708
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/18/2014 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved Missing cover plates throughout the unit. Lights missing globes. Unit lacks smoke detector. Cooler does not operate. Water heater has exposed electrical connections and lacks TPRV pipe that drains to the exterior. Furnace has been removed. Front door does not seal properly and the door frame is deteriorated and broken. Broken front window Kitchen fan does not operate properly. Bedroom has exposed electrical at the fan. Closet light does not operate. Broken window throughout the complex. Exposed electrical junction boxes and light fixtures.
10/28/2014 INSP - FOLLOW UP CODE ENFORCE MENDOZA Approved Unable to gain entry.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T14DV04708
Case Status: NOVERIFY
Total Completed Case Activity Conditions: 2
Date Name
07/22/2014 CONTACTED BY PHONE
10/30/2014 VIOLATION CLOSED

Documents

File Name Document Type  
1ENAVAJO4NOV1.PDF DOCUMENTS VIEW