Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

07/02/2014

Applicant:

VAN HOOK FRED A & ANN F JT/RS

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A HOUSE FIRE, ALARM #14180011 CE18 AREA

Outstanding Inspections

Case Number: T14DV04412
Case Status: COMPLIAN
Case Description: RESIDENTIAL FIRE
Total Outstanding Inspections - 10
End Date Description Inspector Results Comments
09/24/2014 NPO(EL)-MAIN/PANEL/SUB/DISCONT VIDAL Item closed
09/24/2014 NPO(EL)-WIRING/SWITCH/OUTLT/FX VIDAL Item closed
09/24/2014 NPO(PL)-PLUMBING SYSTEM & FX VIDAL Item closed
09/24/2014 NPO(PL)-GAS SUPPLY/CONNECT VIDAL Item closed
09/24/2014 NPO(HC)-COOLING VIDAL Item closed
09/24/2014 NPO(HC)-HEATING & VENTILATION VIDAL Item closed
09/24/2014 NPO - REFUSE/TRASH/DEBRIS VIDAL Item closed
09/24/2014 NPO - EXT. BUILDING MAINTENANC VIDAL Item closed
09/24/2014 NPO - WORK WITHOUT PERMIT VIDAL Item closed
09/24/2014 NPO - INT. BUILDING MAINTENANC VIDAL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T14DV04412
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/29/2014 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Received a call from communication that T.F.D. on site with a house fire. Arrived and the main house was OK but had a fire at a workshop that was added detached from the house. The fire started in the rear of the shop and burned into the shop. Wood fencing was burned with a gate to the desert area. The fencing had wiring along the top rail not in conduit and was for the pool pump and the sprinkler system for the rear yard. The wiring will need to be replaced and install properly for protection. The rear of the workshop was damaged to the wood studs and the wood siding burning the overhang off. The owner was going to secure the workshop and the property can be secured with locking the gates. The power was removed at this time due to the SE. lines had 3-phase and the outer coating has melted off and exposed the wiring on all the conductors. The replacement was scheduled for night time. The conductors will require a different type of POA due to was tied to the fly rafter and was not secured to the structure. T.E.P. gave the owner paperwork on what needs to be done to have the conductors secured properly. Due to have 3-phase this needs to be secured as soon as possible. The interior of the workshop has drywall that was pulled down on the ceiling and walls to check for fire. The rear wall was removed more than half way. The owner signed the paperwork of the indemnification and the N.O.V. The owner removed the wiring to the breaker for the workshop while the power was off to not allow power to the shop until the repairs have been completed. No posting of "Do Not Enter" due to the owner will have the area secured with the locking of the gates to the property. Will check in 30 days. RV.
09/24/2014 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved All the work has been completed and the permit has been finaled on 8-28-14. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T14DV04412
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
09/24/2014 VIOLATION CLOSED

Documents

File Name Document Type  
DSCN4481.JPG IMAGES VIEW
DSCN4465.JPG IMAGES VIEW
DSCN4466.JPG IMAGES VIEW
DSCN4467.JPG IMAGES VIEW
DSCN4468.JPG IMAGES VIEW
DSCN4469.JPG IMAGES VIEW
DSCN4470.JPG IMAGES VIEW
DSCN4471.JPG IMAGES VIEW
DSCN4472.JPG IMAGES VIEW
DSCN4473.JPG IMAGES VIEW
DSCN4474.JPG IMAGES VIEW
DSCN4475.JPG IMAGES VIEW
DSCN4476.JPG IMAGES VIEW
DSCN4477.JPG IMAGES VIEW
DSCN4478.JPG IMAGES VIEW
DSCN4479.JPG IMAGES VIEW
DSCN4480.JPG IMAGES VIEW