Case: T14DV03949
Case Details
Entered Date:
06/17/2014
Applicant:
CAROL KLAMERUS
Description:
WEEDS IN ALLEY / POSSIBLE DILAPITATED STRUCTURE (ROOF/PATIO-COMPLAINTANT NON TENANT)
Case Violations
Case Number: T14DV03949
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 3
| Violation Date | Code Statue |
|---|---|
| 06/23/2014 | T.C. Ch. 16, Sec. 16-11(f)(6) All repair work shall be done in a workman like manner. |
| 06/23/2014 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
| 06/23/2014 | T.C. Ch. 16, Sec. 16-12(e) ACCESSORY STRUCTURES. All accessory structures, including but not limited to detached garages, fences and walls, must be structurally sound and free of disrepair. Examples of disrepair include missing slats, posts or blocks, or damage, deterioration or rot. Fences and walls cannot be constructed or covered with materials not designed or commonly used for that purpose, such as pallets and tarps. Fences and walls must be properly anchored so as not to be in danger of failure or collapse. |
Outstanding Inspections
Case Number: T14DV03949
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/21/2014 | NPO - WEEDS/GRASSES | MENDOZA | Item closed | |
| 10/28/2014 | NPO(DL)-DILAPIDATED STRUCTURE | MENDOZA | Item closed | |
| 10/28/2014 | NPO - EXT. BUILDING MAINTENANC | MENDOZA | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV03949
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/18/2014 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | Laundry/storage room wall severly deteriorated. severe cracking along the walls. The roof of the stucture is deteriorated. Wood members appear to be rotted. Fascia throughout the units are deteriorated and lack proper weather protection. Wood window frames are deteriorated and lack proper weather protection. Wall mounted coolers are not sealed properly. Walls surrounding coolers are deteriorated. Water heater closet at unit 1 is deteriorated. Weeds and grasses exceeding six inches throughout the property. |
| 10/28/2014 | INSP - FOLLOW UP CODE ENFORCE | MENDOZA | Approved | Cooler mounting hardware secure as well as open gaps. Wood window frames have been painted. Water heater closet at unit 1 has been replaced. |
Completed Activity Special Conditions
Case Description - MULTIPLE TYPES
Case Number - T14DV03949
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
| Date | Name |
| 06/23/2014 | CONTACTED BY PHONE |
| 06/27/2014 | CONTACTED BY MAILING |
| 06/27/2014 | NOTICE OF VIOLATION ISSUED |
| 10/29/2014 | VIOLATION CLOSED |
| 06/23/2014 | T.C. Ch. 16, Sec. 16-12(b)(2) WALLS. Exterior walls shall be maintained in a sound condition that is substantially weathertight and weatherproof, and shall be protected from the elements by paint or other approved protective covering. Exterior walls must be free of loose, crumbling or deteriorated plaster or rotted, split or buckled exterior wall coverings. |
| 06/23/2014 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
| 06/23/2014 | T.C. Ch. 16, Sec. 16-13(a) ACCUMULATION OF VEGETATION PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of the accumulation or untended growth of vegetation. The accumulation or untended growth of vegetation means the presence of plants on property that create a fire, safety or health hazard, or that attract vermin either on the property, on neighboring properties, or on both, and includes but is not limited to: (1) Any lawn grass that exceeds 6 inches in height; (2) All weeds that exceed 6 inches in height; (3) Dead trees and dead shrubs; (4) Dead palm fronds within ten feet of the ground, a structure, a fence or wall, or of any combustible other than the tree from which the fronds have grown; (5) Any tree, shrub, or other form of vegetation of any kind on the property or on the adjoining right-of-way, street, or alley that extends over or under the sidewalk space or roadway in a manner that may interfere with the reasonable use of the street, sidewalk, or alley for pedestrian or vehicular traffic of any kind or that may obstruct the view or light distribution of traffic-control devices or luminaries. Vegetation must be trimmed and maintained to provide an unobstructed pedestrian path a minimum 48 inches in width and 80 inches in height from grade. |