Case: T14DV03317
Case Details
Entered Date:
05/21/2014
Applicant:
ALLISON SHELTON / AMANDA OKIFIER
Description:
RMIN: Insect infestation in garbage disposal area. Garbage disposal and dishwasher do not work. Has informed management of miscellaneous housing issues to be repaired.
Case Violations
Case Number: T14DV03317
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 05/29/2014 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 05/29/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 05/29/2014 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 05/29/2014 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 05/29/2014 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
Outstanding Inspections
Case Number: T14DV03317
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 5
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/02/2014 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VALDEZ | Item closed | |
| 07/02/2014 | NPO(PL)-PLUMBING SYSTEM & FX | VALDEZ | Item closed | |
| 07/02/2014 | NPO - INSECTS/PESTS | VALDEZ | Item closed | |
| 07/02/2014 | NPO - SMOKE ALARMS | VALDEZ | Item closed | |
| 07/02/2014 | NPO - INT. BUILDING MAINTENANC | VALDEZ | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV03317
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/28/2014 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | GARBAGE DISPOSAL IN INOPERABLE WHICH CREATES A STRONG SEWER ODOR. THE CEILING FAN WITH LIGHT LOCATED IN THE DINNING AREA IS ALSO INOPERABLE. THE FRONT WINDOW PANE IS DAMAGED. THERE ARE CEILING CRACKS IN THE DRYWALL LOCATED IN THE LIVING ROOM AND THE BEDROOMS. THE SERVICE DISCONNECT HAS NO LABELING. THERE NO SMOKE DETECTORS IN THE BEDROOMS |
| 06/30/2014 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | TENANT HAS MOVED OUT, THE MANAGEMENT COMPANY WANT TO COME IN AND DO MORE WORK TO THE PROPERTY. CLOSE CASE |
Outstanding Case Activity Conditions
| Date | Name | Approved |
| 05/29/2014 | 2011 NATIONAL ELECTRIC CODE ARTICLE 408.4 FIELD IDENTIFICATION REQUIRED. (A) CIRCUIT DIRECTORY OR CIRCUIT IDENTIFICATION. EVERY CIRCUIT AND CIRCUIT MODIFICATION SHALL BE LEGIBLY IDENTIFIED AS TO ITS CLEAR, EVIDENT, AND SPECIFIC PURPOSE OR USE. THE IDENTIFICATION SHALL INCLUDE SUFFICIENT DETAIL TO ALLOW EACH CIRCUIT TO BE DISTINGUISHED FROM ALL OTHERS. SPARE POSITIONS THAT CONTAIN UNUSED OVER CURRENT DEVICES OR SWITCHES SHALL BE DESCRIBED ACCORDINGLY. THE IDENTIFICATION SHALL BE INCLUDED IN A CIRCUIT DIRECTORY THAT IS LOCATED ON THE FACE OR INSIDE OF THE PANEL DOOR IN THE CASE OF A PANEL BOARD, AND LOCATED AT EACH SWITCH OR CIRCUIT BREAKER IN A SWITCH BOARD. NO CIRCUIT SHALL BE DESCRIBED IN A MANNER THAT DEPENDS ON TRANSIENT CONDITIONS OF OCCUPANCY. 2011 NATIONAL ELECTRIC CODE ARTICLE 110.22 IDENTIFICATION OF DISCONNECTING MEANS. (A) GENERAL. EACH DISCONNECTING MEANS SHALL BE LEGIBLY MARKED TO INDICATE ITS PURPOSE UNLESS LOCATED AND ARRANGED SO THE PURPOSE IS EVIDENT. THE MARKING SHALL BE OF SUFFICIENT DURABILITY TO WITHSTAND THE ENVIRONMENT INVOLVED | Not Approved |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV03317
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 05/29/2014 | CONTACTED BY PHONE |
| 05/30/2014 | CONTACTED BY MAILING |
| 05/30/2014 | NOTICE OF VIOLATION ISSUED |
| 07/02/2014 | VIOLATION CLOSED |