Case: T14DV03244
Case Details
Entered Date:
05/19/2014
Applicant:
CARAVANS VII LLC
Description:
Ceiling falling in-living room and flooring in the bathroom and hallway- CE14 AREA
Case Violations
Case Number: T14DV03244
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 6
| Violation Date | Code Statue |
|---|---|
| 06/02/2014 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 06/02/2014 | T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration. |
| 06/02/2014 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
| 06/02/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions. |
| 06/05/2014 | T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room. |
| 06/05/2014 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
Outstanding Inspections
Case Number: T14DV03244
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/02/2014 | NPO - INT. BUILDING MAINTENANC | VINDIOLA | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV03244
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/02/2014 | INSP - INITIAL CODE ENFORCMENT | VINDIOLA | Approved | 06/02/14 - INITIAL INSPECTION CONDUCTED // AV |
| 08/14/2014 | INSP - FOLLOW UP CODE ENFORCE | VINDIOLA | Approved | 08/14/14 - ON SITE WITH TENANT MANANGER AND MAINT MAN // AV |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV03244
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
| Date | Name |
| 05/28/2014 | CONTACTED BY PHONE |
| 06/06/2014 | CONTACTED BY MAILING |
| 05/12/2015 | VIOLATION CLOSED |
| 06/02/2014 | RESEARCH |