Case: T14DV02805
Case Details
Entered Date:
05/05/2014
Applicant:
BAMHP LLC
Description:
No hot water, back door won't lock
Case Violations
Case Number: T14DV02805
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 8
| Violation Date | Code Statue |
|---|---|
| 05/06/2014 | T.C. Ch. 6, IRC adopted. R311.7.8 HANDRAILS. Handrails shall be provided on at least one side of each continuous run of treads or flight with four or more risers. R311.7.8.1 - Height. Handrail height, measured vertically from the sloped plane adjoining the tread nosing, or finish surface of ramp slope, shall be not less than 34 inches (864 mm) and not more than 38 inches (965 mm). |
| 05/06/2014 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 05/06/2014 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 05/06/2014 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 05/06/2014 | T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (5) When a structure is equipped with a gas supply system, it must be installed and maintained in a safe, hazard-free condition. |
| 05/06/2014 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 05/06/2014 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
| 05/06/2014 | T.C. Ch. 16, Sec. 16-12(a)(3) BOARDED WINDOW OR DOOR OPENINGS. a. No occupied structure may have boarded window or door openings, except as necessary on a temporary basis to keep the structure secure while under repair. b. While vacant structures may temporarily be secured by boarding up window and door openings in accordance with section 16-14(b), having or maintaining boarded window or door openings on a vacant structure for 180 days or more in any one-year period is prohibited. |
Outstanding Inspections
Case Number: T14DV02805
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 6
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/17/2014 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | STEVENS | Item closed | |
| 06/17/2014 | NPO(PL)-PLUMBING SYSTEM & FX | STEVENS | Item closed | |
| 06/17/2014 | NPO(PL)-GAS SUPPLY/CONNECT | STEVENS | Item closed | |
| 06/17/2014 | NPO - SMOKE ALARMS | STEVENS | Item closed | |
| 06/17/2014 | NPO - EXT. BUILDING MAINTENANC | STEVENS | Item closed | |
| 06/17/2014 | NPO - INT. BUILDING MAINTENANC | STEVENS | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T14DV02805
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/05/2014 | INSP - INITIAL CODE ENFORCMENT | STEVENS | Approved | At site I spoke to manager and tenant. No pipe on temp/pressure valve on water heater. Water heater gas is shut off at regulator valve. No covers on outlets or light swiches throughout the trailer. Back door is boarded up, no access. No smoke detectors. The valve on the oven is broken, there is no stop on the valve to shut of the oven. Hole under the bathroom sink leads to the outside. Bathroom door is to small for the opening and there is no door knob. Broken windows in the front of the home. Rear bedroom has a hole leading to the outside. No hand rail on steps to front door. |
| 06/16/2014 | INSP - FOLLOW UP CODE ENFORCE | STEVENS | Approved | At site, trailer is vacant. Walked through trailer with manager. All issues are abated. Close case. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T14DV02805
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
| Date | Name |
| 05/06/2014 | CONTACTED BY MAILING |
| 05/06/2014 | NOTICE OF VIOLATION ISSUED |
| 06/17/2014 | VIOLATION CLOSED |